SI-I/O User Guide
25
Issue Number: 3
Analog Output 1 Source (Pr
S.03.006
) defines the source parameter for T11 analog output 1.
The analog output is only available on Unidrive M600 - M800.
Analog Output 1 Scaling (Pr
S.03.007
) defines the scaling that is applied to T11 analog output 1.
The analog output is only available on Unidrive M600 - M800.
S.03.006
Analog Output 1 Source
Minimum
0.00.000
Maximum
4.99.999
Default
0.00.000
Units
Type
32 Bit User Save
Update Rate
Background read
Display Format
Slot Menu
Parameter
Decimal Places
Coding
RW, BU
S.03.007
Analog Output 1 Scaling
Minimum
0.000
Maximum
40.000
Default
1.000
Units
Type
16 Bit User Save
Update Rate
Background read
Display Format
None
Decimal Places
3
Coding
RW, BU
S.03.011
Analog Input 1 Offset
S.03.021
Analog Input 2 Offset
S.03.031
Analog Input 3 Offset
S.03.041
Differential Analog Input Offset
Minimum
-100.00
Maximum
100.00
Default
0.00
Units
%
Type
16 Bit User Save
Update Rate
Background read
Display Format
None
Decimal Places
2
Coding
RW
S.03.012
Analog Input 1 Scaling
S.03.022
Analog Input 2 Scaling
S.03.032
Analog Input 3 Scaling
S.03.042
Differential Analog Input Scaling
Minimum
0.000
Maximum
40.000
Default
1.000
Units
Type
16 Bit User Save
Update Rate
Background read
Display Format
None
Decimal Places
3
Coding
RW, BU
NOTE