AX100-Series - Installing a Fibre Channel Storage System with a Direct Connection to a NetWare Server
43
Initializing the Storage System
7. In the message box about the storage system having been
initialized, click
OK
.
If you entered an SP IP address for the first time or changed an SP
IP address, the utility reboots the storage system and the
SP Boot/Fault light on the back of each SP starts blinking
(Figure 17). The reboot takes several minutes to complete. When
it has completed, the SP Boot/Fault light on each SP stops
blinking and remains off.
Figure 17
SP Boot/Fault and Power Supply Fault Lights (AX100 Shown)
If you installed the Navisphere Storage System Initialization Utility
on a server (a host that will have data access to the storage-system
disks), leave the utilities CD in the drive because you will need it to
install the Navisphere Server Utility on the server. If you installed the
Navisphere Storage System Initialization utility on a host that you
will use
only
to initialize or manage the storage system (a host that
will have
no data
access to the storage-system disks), remove the CD
from the drive.
Install the Navisphere Storage System Initialization Utility on a NetWare Host
1. Insert the
AX-Series Server Support
CD into the CD drive of the
computer on the same subnet as the storage system.
2. Log in to the NetWare server as a user with privileges for the
SYS
volume.
You can log in as admin or any user with administrative
privileges.
3. From a NetWare client, map a drive to the NetWare server’s
SYS
volume.
For example:
H:
FE 0
FE 1
FE 0
FE 1
Power
SP A Boot/Fault
Power Supply A Fault
Power Supply B Fault
SP B Boot/Fault
EMC2928d
SP B
SP A