14
AX100-Series - Installing a Fibre Channel Storage System with a Direct Connection to a NetWare Server
Installing the Navisphere Server Utility
For example:
cd D: /NETWARE/NAVIHOST
b. From the NetWare client command prompt, enter
INSTALL
drive
where
drive
is the remote drive corresponding to the SYS
volume on the NetWare server.
For example,
INSTALL H:
would cause the installation script
to create the
H:\EMC\NAVIHOST
directory with all the
required Navisphere Server Utility subdirectories.
6. Set the utility to restart automatically each time the server
reboots:
a. On the NetWare server, enter
NWCONFIG
b. From the
Installation Options
menu, follow the path
NCF files options > Available NCF Files Options > Edit
AUTOEXEC.NCF file
c. Add the following command to the end of the
AUTOEXEC.NCF
file:
LOAD SYS:\EMC\NAVIHOST\AXNAVHST UPDATE
d. Press
ESC
.
e. At the prompt to save the
AUTOEXEC.NCF
files, click
Yes
and press
ESC
twice.
f. At the prompt to exit the install process, click
Yes
.
7. Remove the CD from the CD drive.