![EMC VCE VxRail 120 Product Manual Download Page 62](http://html1.mh-extra.com/html/emc/vce-vxrail-120/vce-vxrail-120_product-manual_2399738062.webp)
Hardware acclimation times (systems and components)
Table 8:
If the last 24 hours of the TRANSIT/
STORAGE environment was this:
…and the OPERATING environment
is this:
…then let the system or
component acclimate in the
new environment this many
hours:
Cold
<68°F (20°C)
Damp
≥30% RH
<86°F (30°C)
4 hours
Hot
>72°F (22°C)
Dry
<30% RH
<86°F (30°C)
4 hours
Hot
>72°F (22°C)
Humid 30-45%
RH
<86°F (30°C)
4 hours
Humid 45-60%
RH
<86°F (30°C)
8 hours
Humid ≥60%
RH
<86°F (30°C)
16 hours
Unknown
<86°F (30°C)
16 hours
•
If there are signs of condensation after the recommended acclimation time has
passed, allow an additional eight (8) hours to stabilize.
•
Systems and components must not experience changes in temperature and
humidity that are likely to cause condensation to form on or in that system or
component. Do not exceed the shipping and storage temperature gradient of
45°F/hr (25°C/hr).
Unpacking a part
Procedure
1
Wear ESD gloves or attach an ESD wristband to your wrist and the enclosure in which you are
installing the part.
2
Unpack the part and place it on a static-free surface.
3
If the part is a replacement for a faulted part, save the packing material to return the faulted part.
Replacing HDD and SSD drives
VxRail Manager provides automated assistance with replacing disks (HDDs and SSDs) in your VxRail
Appliance.
Although VxRail Manager simplifies the replacement procedure, only qualified personnel should perform
these procedures.
VCE VxRail
™
Appliance 3.5 Product Guide
Replacing hardware