29
Serial/Ethernet Communication (SCOM) Interface
IND100084-14
MCC Command
Syntax and Functionality
Details and Values
PIP, PBP Contrast Control
Syntax : 07 FF 4D 43 43 03 23
A3
xx yy
zz
Function Examples:
Example "50" : 07 FF 4D 43 43 03 23
A3
35 30
F7
Query "?" : 07 FF 4D 43 43 02 24
A3
3F
1D
Reset "R" : 07 FF 4D 43 43 02 24
A3
52
0A
Reset "r" : 07 FF 4D 43 43 02 24
A3
72
EA
Increase "+" : 07 FF 4D 43 43 02 24
A3
2B
31
Decrease "-" : 07 FF 4D 43 43 02 24
A3
2D
2F
Where
xx
= "0" to "6"
Where
yy
= "0" to "F"
Where
zz
= Calculated Checksum
Max Range: "0" "0" to "6" "4"
Default: "3" "2"
PIP Horizontal Position
Note:
Not available on STD units.
Syntax : 07 FF 4D 43 43 03 23
A4
xx yy
zz
Function Examples:
Example "50" : 07 FF 4D 43 43 03 23
A4
35 30
F6
Query "?" : 07 FF 4D 43 43 02 24
A4
3F
1C
Reset "R" : 07 FF 4D 43 43 02 24
A4
52
09
Reset "r" : 07 FF 4D 43 43 02 24
A4
72
E9
Increase "+" : 07 FF 4D 43 43 02 24
A4
2B
30
Decrease "-" : 07 FF 4D 43 43 02 24
A4
2D
2E
Where
xx
= "0" to "6"
Where
yy
= "0" to "F"
Where
zz
= Calculated Checksum
Max Range: "0" "0" to "6" "4"
Default: "6" "4"
PIP Vertical Position
Note:
Not available on STD units.
Syntax : 07 FF 4D 43 43 03 23
A5
xx yy
zz
Function Examples:
Example "50" : 07 FF 4D 43 43 03 23
A5
35 30
F5
Query "?" : 07 FF 4D 43 43 02 24
A5
3F
1B
Reset "R" : 07 FF 4D 43 43 02 24
A5
52
08
Reset "r" : 07 FF 4D 43 43 02 24
A5
72
E8
Increase "+" : 07 FF 4D 43 43 02 24
A5
2B
2F
Decrease "-" : 07 FF 4D 43 43 02 24
A5
2D
2D
Where
xx
= "0" to "6"
Where
yy
= "0" to "F"
Where
zz
= Calculated Checksum
Max Range: "0" "0" to "6" "4"
Default: "6" "4"
PIP Window Size Select
Note:
Not available on STD units.
Syntax : 07 FF 4D 43 43 02 24
A6
xx
zz
Function Examples:
Example "4" : 07 FF 4D 43 43 02 24
A6
34
25
Query "?" : 07 FF 4D 43 43 02 24
A6
3F
1A
Reset "R" : 07 FF 4D 43 43 02 24
A6
52
07
Reset "r" : 07 FF 4D 43 43 02 24
A6
72
E7
Increase "+" : 07 FF 4D 43 43 02 24
A6
2B
2E
Decrease "-" : 07 FF 4D 43 43 02 24
A6
2D
2C
Where
xx
= "1" to "7"
Where
zz
= Calculated Checksum
Default: "7"
Second Source Select
Note:
Not available on STD units.
Syntax : 07 FF 4D 43 43 02 24
A7
xx
zz
Function Examples:
Example "4" : 07 FF 4D 43 43 02 24
A7
34
24
Query "?" : 07 FF 4D 43 43 02 24
A7
3F
19
Reset "R" : 07 FF 4D 43 43 02 24
A7
52
06
Reset "r" : 07 FF 4D 43 43 02 24
A7
72
E6
Where
xx
= "0" to "6"
Where
zz
= Calculated Checksum
Available functions:
"0" = Digital 1 (default)
"1" = Digital 2
"2" = Analog RGB1
"3" = Analog RGB2
"4" = Composite 1
"5" = Composite 2
"6" = Composite 3
Color Temperature Select
Syntax : 07 FF 4D 43 43 02 24
B3
xx
zz
Function Examples:
Example "2" : 07 FF 4D 43 43 02 24
B3
32
1A
Query "?" : 07 FF 4D 43 43 02 24
B3
3F
0D
Reset "R" : 07 FF 4D 43 43 02 24
B3
52
FA
Reset "r" : 07 FF 4D 43 43 02 24
B3
72
DA
Where
xx
= "0" to "3"
Where
zz
= Calculated Checksum
Available functions:
"0" = 9300K
"1" = 8000K (default)
"2" = 6500K
"3"
=
USER
Examples on Response:
"8" "0" "0" "0" (8000k)
"U" "S" "E" "R" (USER)
Red Level for Selected Color
Temperature
Note:
Available function list differs
between MMD and STD units!
Syntax : 07 FF 4D 43 43 03 23
B4
xx yy
zz
Function Examples:
Example "50" : 07 FF 4D 43 43 03 23
B4
35 30
E6
Query "?" : 07 FF 4D 43 43 02 24
B4
3F
0C
Reset "R" : 07 FF 4D 43 43 02 24
B4
52
F9
Reset "r" : 07 FF 4D 43 43 02 24
B4
72
D9
Increase "+" : 07 FF 4D 43 43 02 24
B4
2B
20
Decrease "-" : 07 FF 4D 43 43 02 24
B4
2D
1E
Where
xx
= "0" to "6"
Where
yy
= "0" to "F"
Where
zz
= Calculated Checksum
Max Range: "0" "0" to "6" "4"
Default MMD: "3" "2"
Default STD: "6" "4"