26
Serial/Ethernet Communication (SCOM) Interface
IND100084-14
MCC Command
Syntax and Functionality
Details and Values
Scaling Mode
Note:
Not available on STD units.
Syntax : 07 FF 4D 43 43 02 24
8C
xx
zz
Function Examples:
Example "2" : 07 FF 4D 43 43 02 24
8C
32
41
Query "?" : 07 FF 4D 43 43 02 24
8C
3F
34
Reset "R" : 07 FF 4D 43 43 02 24
8C
52
21
Reset "r" : 07 FF 4D 43 43 02 24
8C
72
01
Where
xx
= "0" to "2"
Where
zz
= Calculated Checksum
Available functions:
"0" = Full (default)
"1" = 1:1
"2" = Fill to aspect ratio
OSD Lock Mode
Syntax : 07 FF 4D 43 43 02 24
8D
xx
zz
Function Examples:
Example "1" : 07 FF 4D 43 43 02 24
8D
31
41
Query "?" : 07 FF 4D 43 43 02 24
8D
3F
33
Reset "R" : 07 FF 4D 43 43 02 24
8D
52
20
Reset "r" : 07 FF 4D 43 43 02 24
8D
72
00
Where
xx
= "0" to "2"
Where
zz
= Calculated Checksum
Available functions:
"0" = Normal (default)
"1" = Full Protection
"2" = Menu Protection
Auto Adjustment
Note:
Not available on STD units.
Syntax : 07 FF 4D 43 43 02 24
8F
xx
zz
Function Examples:
Example "1" : 07 FF 4D 43 43 02 24
8F
31
3F
Query "?" : 07 FF 4D 43 43 02 24
8F
3F
31
Reset "R" : 07 FF 4D 43 43 02 24
8F
52
1E
Reset "r" : 07 FF 4D 43 43 02 24
8F
72
FE
Where
xx
= "0" to "1"
Where
zz
= Calculated Checksum
Available functions:
"0" = Off
"1" = On (default)
OSD Horizontal Position
Syntax : 07 FF 4D 43 43 03 23
90
xx yy
zz
Function Examples:
Example "50" : 07 FF 4D 43 43 03 23
90
35 30
0A
Query "?" : 07 FF 4D 43 43 02 24
90
3F
30
Reset "R" : 07 FF 4D 43 43 02 24
90
52
1D
Reset "r" : 07 FF 4D 43 43 02 24
90
72
FD
Increase "+" : 07 FF 4D 43 43 02 24
90
2B
44
Decrease "-" : 07 FF 4D 43 43 02 24
90
2D
42
Where
xx
= "0" to "6"
Where
yy
= "0" to "F"
Where
zz
= Calculated Checksum
Max Range: "0" "0" to "6" "4"
Default: "3" "2"
Note: If Value > 100 then Value=100.
If Value is not multiple by ten, it
change to less nearest multiple
value.
OSD Vertical Position
Syntax : 07 FF 4D 43 43 03 23
91
xx yy
zz
Function Examples:
Example "50" : 07 FF 4D 43 43 03 23
91
35 30
09
Query "?" : 07 FF 4D 43 43 02 24
91
3F
2F
Reset "R" : 07 FF 4D 43 43 02 24
91
52
1C
Reset "r" : 07 FF 4D 43 43 02 24
91
72
FC
Increase "+" : 07 FF 4D 43 43 02 24
91
2B
43
Decrease "-" : 07 FF 4D 43 43 02 24
91
2D
41
Where
xx
= "0" to "6"
Where
yy
= "0" to "F"
Where
zz
= Calculated Checksum
Max Range: "0" "0" to "6" "4"
Default: "3" "2"
Note: If Value > 100 then Value=100.
If Value is not multiple by ten, it
change to less nearest multiple
value.
OSD Transparency
Note:
Not available on STD units.
Syntax : 07 FF 4D 43 43 02 24
92
xx
zz
Function Examples:
Example "2" : 07 FF 4D 43 43 02 24
92
32
3B
Query "?" : 07 FF 4D 43 43 02 24
92
3F
2E
Reset "R" : 07 FF 4D 43 43 02 24
92
52
1B
Reset "r" : 07 FF 4D 43 43 02 24
92
72
FB
Increase "+" : 07 FF 4D 43 43 02 24
92
2B
42
Decrease "-" : 07 FF 4D 43 43 02 24
92
2D
40
Where
xx
= "0" to "7"
Where
zz
= Calculated Checksum
Default: "0"
Select OSD Menu Timeout
Note:
Not available on STD units.
Syntax : 07 FF 4D 43 43 03 23
93
xx yy
zz
Function Examples:
Example "10" : 07 FF 4D 43 43 03 23
93
31 30
0B
Query "?" : 07 FF 4D 43 43 02 24
93
3F
2D
Reset "R" : 07 FF 4D 43 43 02 24
93
52
1A
Reset "r" : 07 FF 4D 43 43 02 24
93
72
FA
Increase "+" : 07 FF 4D 43 43 02 24
93
2B
41
Decrease "-" : 07 FF 4D 43 43 02 24
93
2D
3F
Where
xx
= "0" to "1"
Where
yy
= "0" to "E"
Where
zz
= Calculated Checksum
Max Range: "0" "0" to "1" "E"
Default: "0" "A"