30
Serial/Ethernet Communication (SCOM) Interface
IND100084-14
MCC Command
Syntax and Functionality
Details and Values
Green Level for Selected Color
Temperature
Note:
Available function list differs
between MMD and STD units!
Syntax : 07 FF 4D 43 43 03 23
B5
xx yy
zz
Function Examples:
Example "50" : 07 FF 4D 43 43 03 23
B5
35 30
E5
Query "?" : 07 FF 4D 43 43 02 24
B5
3F
0B
Reset "R" : 07 FF 4D 43 43 02 24
B5
52
F8
Reset "r" : 07 FF 4D 43 43 02 24
B5
72
D8
Increase "+" : 07 FF 4D 43 43 02 24
B5
2B
1F
Decrease "-" : 07 FF 4D 43 43 02 24
B5
2D
1D
Where
xx
= "0" to "6"
Where
yy
= "0" to "F"
Where
zz
= Calculated Checksum
Max Range: "0" "0" to "6" "4"
Default MMD: "3" "2"
Default STD: "6" "4"
Blue Level for Selected Color
Temperature
Note:
Available function list differs
between MMD and STD units!
Syntax : 07 FF 4D 43 43 03 23
B6
xx yy
zz
Function Examples:
Example "50" : 07 FF 4D 43 43 03 23
B6
35 30
E4
Query "?" : 07 FF 4D 43 43 02 24
B6
3F
0A
Reset "R" : 07 FF 4D 43 43 02 24
B6
52
F7
Reset "r" : 07 FF 4D 43 43 02 24
B6
72
D7
Increase "+" : 07 FF 4D 43 43 02 24
B6
2B
1E
Decrease "-" : 07 FF 4D 43 43 02 24
B6
2D
1C
Where
xx
= "0" to "6"
Where
yy
= "0" to "F"
Where
zz
= Calculated Checksum
Max Range: "0" "0" to "6" "4"
Default MMD: "3" "2"
Default STD: "6" "4"
Graphic Horizontal Resolution
Query
Send Only : 07 FF 4D 43 43 01 25
B7
48
Available response status:
"xxx" = where xxx is a 3-digit HEX
number indicating resolution.
Example:
"0640" = 1600 in decimal
Graphic Vertical Resolution
Query
Send Only : 07 FF 4D 43 43 01 25
B8
47
Available response status:
"xxx" = where xxx is a 3-digit HEX
number indicating resolution.
Example:
"0480" = 1200 in decimal
Graphic Horizontal Sync.
Frequency
Send Only : 07 FF 4D 43 43 01 25
B9
46
Available response status:
"xxx" = where xxx is a 3-digit HEX
number indicating frequency in units
of 100Hz.
Example:
"29F" = 671 or 67.1 kHz decimal
Graphic Vertical Sync.
Frequency
Send Only : 07 FF 4D 43 43 01 25
BA
45
Available response status:
"xxx" = where xxx is a 3-digit HEX
number indicating frequency in units
of 0.1Hz + 1 character indicating
field mode as:
"i" = Interlaced
"p" = Progressive
Example:
"256p" = 598 (59.8 Hz),
progressive fields
Set Address RS / Serial
Syntax : 07 FF 4D 43 43 02 24
BB
xx
zz
Function Examples:
Example "9" : 07 FF 4D 43 43 02 24
BB
39
0B
Where
xx
= "0" to "F"
Where
zz
= Calculated Checksum