28
Serial/Ethernet Communication (SCOM) Interface
IND100084-14
MCC Command
Syntax and Functionality
Details and Values
Gamma (Calibration) Select
Note:
Available function list differs
between MMD and STD units!
Syntax : 07 FF 4D 43 43 02 24
9D
xx
zz
Function Examples:
Example "1" : 07 FF 4D 43 43 02 24
9D
31
31
Query "?" : 07 FF 4D 43 43 02 24
9D
3F
23
Reset "R" : 07 FF 4D 43 43 02 24
9D
52
10
Reset "r" : 07 FF 4D 43 43 02 24
9D
72
F0
Where
xx
= "0" to "2" or "1" to "2"
Where
zz
= Calculated Checksum
Available functions (MMD):
"0" = Calibration VGA
"1" = Calibration DVI
"2" = No Calibration (default)
Available functions (STD):
"1" = Calibration Mode
"2" = Color Temperature (default)
Power Saving / Up
Syntax : 07 FF 4D 43 43 02 24
9E
xx
zz
Function Examples:
Example "0" : 07 FF 4D 43 43 02 24
9E
30
31
Query "?" : 07 FF 4D 43 43 02 24
9E
3F
22
Reset "R" : 07 FF 4D 43 43 02 24
9E
52
0F
Reset "r" : 07 FF 4D 43 43 02 24
9E
72
EF
Where
xx
= "0" to "1"
Where
zz
= Calculated Checksum
Available functions:
"0" = Sleeping Mode
"1" = Normal Mode (default)
Power Down / Up
Syntax : 07 FF 4D 43 43 02 24
9F
xx
zz
Function Examples:
Example "1" : 07 FF 4D 43 43 02 24
9F
31
2F
Query "?" : 07 FF 4D 43 43 02 24
9F
3F
21
Reset "R" : 07 FF 4D 43 43 02 24
9F
52
0E
Reset "r" : 07 FF 4D 43 43 02 24
9F
72
EE
Where
xx
= "0" to "1"
Where
zz
= Calculated Checksum
Available functions:
"0" = Power Off
"1" = Power On (default)
Direct Access
Note:
Not available on STD units.
Syntax : 07 FF 4D 43 43 03 23
A0
xx yy
zz
Function Examples:
Example "19" : 07 FF 4D 43 43 03 23
A0
31 39
F5
Query "?" : 07 FF 4D 43 43 02 24
A0
3F
20
Reset "R" : 07 FF 4D 43 43 02 24
A0
52
0D
Reset "r" : 07 FF 4D 43 43 02 24
A0
72
ED
Where
xx
= "1" to "2"
Where
yy
= "0" to "A"
Where
zz
= Calculated Checksum
Available functions (
xx
):
"1" - Hot Key 1
"2" - Hot Key 2
Available functions (
yy
):
"0" - Brightness
"1" - PIP size
"2" - Main source
"3" - Second source
"4" - PIP mode
"5" - Scaling
"6" - Swap
"7" - Test pattern
"8" - LED drive
"9" - Language
"A" - No function (default)
PIP, PBP Brightness Control
Syntax : 07 FF 4D 43 43 03 23
A2
xx yy
zz
Function Examples:
Example "50" : 07 FF 4D 43 43 03 23
A2
35 30
F8
Query "?" : 07 FF 4D 43 43 02 24
A2
3F
1E
Reset "R" : 07 FF 4D 43 43 02 24
A2
52
0B
Reset "r" : 07 FF 4D 43 43 02 24
A2
72
EB
Increase "+" : 07 FF 4D 43 43 02 24
A2
2B
32
Decrease "-" : 07 FF 4D 43 43 02 24
A2
2D
30
Where
xx
= "0" to "6"
Where
yy
= "0" to "F"
Where
zz
= Calculated Checksum
Max Range: "0" "0" to "6" "4"
Default: "3" "2"