31
Serial/Ethernet Communication (SCOM) Interface
IND100084-14
MCC Command
Syntax and Functionality
Details and Values
Set IP Address (fixed or auto)
Note:
By sending this command, the
communication mode will be
automatically set to "Ethernet",
in the
"Communication Mode"
,
referenced earlier in this chapter.
In addition, a power off/on to
the unit is required to reboot the
internal network code and utilize
the newly set IP address. This
can either be done by issue the
"Power down / up"
command
described earlier in this table or
do a physical power off/on for
the unit.
This command is not available
on STD units.
Syntax : 07 FF 4D 43 43 10 16
BC
v1 v2 v3
2E
w1
W2 W3
2E
x1 x2 x3
2E
y1 y2 y3
zz
Function Examples:
Example fixed IP 192.168.1.35, Send:"192.168.001.035":
07 FF 4D 43 43 10 16
BC
31 39 32
2E
31 36 38
2E
30 30
31
2E
30 33 35
55
Set Auto IP "A" : 07 FF 4D 43 43 02 24
BC
41
02
Set Auto IP "a" : 07 FF 4D 43 43 02 24
BC
61
E2
Where
v1
= "0" to "2"
Where
v2
= "0" to "9"
Where
v3
= "0" to "9"
Where
w1
= "0" to "2"
Where
w2
= "0" to "9"
Where
w3
= "0" to "9"
Where
x1
= "0" to "2"
Where
x2
= "0" to "9"
Where
x3
= "0" to "9"
Where
y1
= "0" to "2"
Where
y2
= "0" to "9"
Where
y3
= "0" to "9"
Where 2E = "." (dot)
Where
zz
= Calculated Checksum
or
Where
v1
= "a" or "A" (Auto IP)
Where
zz
= Calculated Checksum
Available response status:
"0" = Fail
"1" = Successful
Auto Position
Note:
PC mode only.
Send Only : 07 FF 4D 43 43 01 25
C3
3C
Available response status:
"0" = Fail
"1" = Successful
Auto Color Balance
Send Only : 07 FF 4D 43 43 01 25
C5
3A
Available response status:
"0" = Fail
"1" = Successful
OSD Outdoor Mode
Syntax : 07 FF 4D 43 43 02 24
CA
xx
zz
Function Examples:
Example "1" : 07 FF 4D 43 43 02 24
CA
31
04
Where
xx
= "0" to "1"
Where
zz
= Calculated Checksum
Available functions:
"0" = No delay for all touch
buttons, except 2 sec delay
for "MENU"
"1" = Delay 5 seconds for all touch
buttons
Burn In
Syntax : 07 FF 4D 43 43 02 24
CC
xx
zz
Function Examples:
Example "1" : 07 FF 4D 43 43 02 24
CC
39
0B
Query "?" : 07 FF 4D 43 43 02 24
CC
3F
F4
Reset "R" : 07 FF 4D 43 43 02 24
CC
52
E1
Reset "r" : 07 FF 4D 43 43 02 24
CC
72
C1
Where
xx
= "0" to "1"
Where
zz
= Calculated Checksum
Available functions:
"0" = Normal Mode
"1" = Burin In Mode
Test Pattern
Syntax : 07 FF 4D 43 43 02 24
CD
xx
zz
Function Examples:
Example "1" : 07 FF 4D 43 43 02 24
CD
31
01
Where
xx
= "0" to "1"
Where
zz
= Calculated Checksum
Available functions:
"0" = Normal Display
"1" = Display built-in Test Pattern
Reset Factory Default
Send Only : 07 FF 4D 43 43 01 25
CE
31
Available response status:
"0" = fail
"1" = successful
Save User Default
Note:
Available function list differs
between MMD and STD units!
Syntax : 07 FF 4D 43 43 02 24
D7
xx
zz
Function Examples:
Example "3" : 07 FF 4D 43 43 02 24
D7
33
F5
Where
xx
= "1" to "5"
Where
zz
= Calculated Checksum
Available functions (MMD):
"1" = User1 Slot
"2" = User2 Slot
"3" = User3 Slot
"4" = User4 Slot
"5" = User5 Slot
Available functions (STD):
"1" = User Slot
Available response status:
"0" = Fail
"1" = Successful