background image

TABLE OF

CONTENT

WARNINGS AND SAFETY INSTRUCTIONS

1. IMPORTANT SAFETY INSTRUCTIONS

3. CONTROL AND DISPLAY PANEL

4. OPERATION PROCEDURE

5. PRIMING SETTING

7. SYSTEM RESET TO FACTORY DEFAULT SETTING

8. AUTO-RECOVERY

10. ERRORS DESCRIPTION

11. WI-FI SETTING

12. ROUTINE MAINTENANCE

13. AFTER-SALES  SERVICE

15. REPLACEMENT PARTS

16. SPECIFICATION AND PUMP CURVE

17. TROUBLE SHOOTING

18. WARRANTY POLICY

P

A

G

E

2

....

4

4

5

....

....

....

7

....

2. INSTALLATION

6. RS485 SETTING

9. ERROR MENU

14. DIMENSIONS

11

....

12

....

13

....

13

....

14

....

14

....

15

....

18

....

18

....

18

....

19

....

20

....

20

....

21

....

P1    CONTENT

S

U

P

E

R P

O

W

E

R

WARRANTY POLICY    P22

18

.

1 EXCEPTIONS

 

THAT

 

MAY RESULT IN DENIAL

 

OF A WARRANTY CLAIM:

 

1. Damage caused by careless handling, improper repackaging or shipping.

2. Damage due to misapplication, misuse, abuse or failure to operate and install the equipment as specified in this 

manual.

3.  Damage  caused  by  a  misuse,  abuse  or  failure  to  operate  and  install  the  equipment  out  of  the  scope  of  a 

professional level demanded in similar equipment or installation type.

4. Damage due to unauthorized product modifications or failure to use Emaux original replacement parts.

5. Damaged caused by negligence or failure to properly maintain products as specified in this manual.

6. Damage caused by failure to maintain water chemistr y in conformity with the standards of the swimming pool 

industr y for any length of time.

7. Damage caused by water freezing inside the product.

8. Accident damage, fire or other circumstances outside the control of Emaux.

9. Items had been repaired or altered in any way by any person that is not authorized by Emaux.

10. Wear & tear parts.

18.2 CLAIM

 

PROCESS

Summar y of Emaux Claim Process in 3 steps:

1. Claim: Customer contacts Emaux salesperson and provides completed details of the claim which includes:

(1) Information about the failed product such as the part number(s) and serial number(s).

(2) Description of the complaint/failure.

(3) Pictures

2. Once the complaint is received, the product quality incident will then be reviewed by Emaux's Quality Control 

Department following the “Emaux Warranty Policy”.

3. Conclusion: After the investigation is completed, Emaux will inform the distributor accordingly.

18.3

 

WARRANTY OBLIGATION

 

Emaux warrants any of above items from workmanship and/or material(s).

Should a defect become evident during the term of warranty, Emaux will, at its option, repair or replace such item or part at its 

own cost and expense. Customer will need to follow the warranty claim procedures from Emaux in order to obtain the benefit 

on this warranty.

Emaux is not, however, responsible under this warranty for any cost of shipping or transportation of the equipment or parts 

thereof “to” or “from” our technical operations. 

Emaux is not able to liable for any loss of time, inconvenience, incidental expenses such as labor cost, phone calls, legal cost or 

material  cost  incurred  in  connection  with  the  replacement  or  removal  of  the  equipment,  or  any  other  consequential  or 

incidental damage on persons or assets. Emaux will be not responsible for any business profit loss operation stop due to the 

non-conformity product equipment. No indemnity or damages can be claimed on any account whatever.

18.4 WARRANTY OR REPRESENTATIONS BY OTHERS

No dealer or other person has authority to make any warranty or representation concerning Emaux or its products.

Accordingly, Emaux is not responsible for any such warranty or representation.

VA

R

IA

B

L

E S

P

E

E

D P

U

M

P

Summary of Contents for SPV Series

Page 1: ...MANUAL SUPER POWER VARIABLE SPEED PUMP With Wi Fi AND MODBUS OPTIONS NSF only apply for NSF version Model SPV Series SAA STRIVE FOR CLEAR WATER www emauxgroup com EMAUX WATER TECHNOLOGY CO LTD EMPU210...

Page 2: ...mmary of Emaux Claim Process in 3 steps 1 Claim Customer contacts Emaux salesperson and provides completed details of the claim which includes 1 Information about the failed product such as the part n...

Page 3: ...erate under high pressure When any part of the circulating system i e lock ring pump filter valves etc is serviced air can enter the system and become pressurized Filter tank Lid and pre filter cover...

Page 4: ...Entrapment or entanglement hair is pulled into and or wrapped around the grate of the drain cover 4 Mechanical Entrapment the bather s jewelry or clothing gets caught in the drain or the grate 5 Evisc...

Page 5: ...ure 2 Place the pump as close to the water source as possible so that the suction pipe is short straight and direct to reduce the friction loss Don t install the pump at more than 10ft 3 meters of geo...

Page 6: ...Running speed and power rating display 3 Pre set Speed 3 pre set running speeds 4 Function settings Real time clock 3 pre set speeds 2 schedule settings NO flow self priming settings 5 Error display O...

Page 7: ...re Version Su00x Reset RESET Title Value Operation Light Start Stop Increase Page Up Decrease Page Down Mode Setting Preset Speed 1 Preset Speed 2 Preset Speed 3 Quick Setting Quick Setting Quick Sett...

Page 8: ...ble and disable switch at the end of each setting to turn it ON or OFF 5 Freeze protection default temperature is 4 degree C in 4 or 8 hours running in setting speed 6 To do any change touch save to s...

Page 9: ...ect connection is a ONE To ONE connection without access Home Network It is just like a private controller It can be connected and control by mobile phone tablet PC laptop top or any Wi Fi enable devi...

Page 10: ...r details and all lights will start flashing Press Run shortly at the error menu to auto recover the variable speed driver keep the driver Off 10 ERRORS DESCRIPTION 10 1 COMMUNICATION ERROR If the com...

Page 11: ...other When there is an error the variable speed driver will restore the settings to those before the error The priority setting is still applicable P13 SYSTEM RESET TO FACTORY DEFAULT SETTING 7 SYSTE...

Page 12: ...ation interface for external automation controller It is not for domestic user access purpose It is an always ready to interface for external automation control The pin assignment is 1 A and 2 B The w...

Reviews: