P9    OPERATION PROCEDURE

1

Short press “Speed 1 “and “Speed 2” to shift between Hour and Minute. The adjustable value digital is flashing. 

2

Press “

” or “

” to adjust the value.  

3

Short press “Mode” to save setting or press “Speed 3” for cancel

▼  

1. Long Press “Mode” to access 

schedule 1

 setting. Default speed is 1500RPM.

2.

 

The corresponding speed is “Speed 1” and it can't be changed from this point. It needs to change from Speed 1-3 

setting procedure as above. 

3. Short press “

” or “

”  to set 

START TIME

 (1o:00:00). Default is 00:00

▼  

1. Short press “

” or “

” to set the 

END TIME

 (IF:00:00) . Default is 00:00

2

.

Short press “Speed 1 “and “Speed 2” to shift between Hour and Minute. The adjustable value digital is flashing. 

3

Press “

” or ”

▼  

to adjust the value.  

4

Short press “Mode” to save setting or press “Speed 3” for cancel

5

Short press “

” or “

 

to access ON or OFF setting. Default is OFF

ERROR MENU    P14

Press  “Run”  to  cancel  the  procedures  and  to  auto-recover  immediately  (the  default  settings  of  the  variable 

speed driver will appear). 

9. ERROR MENU

The Error Menu display will show all error details and all lights will start flashing. Press “Run” shortly at the error 

menu, to auto-recover the variable speed driver (keep the driver Off).

10. ERRORS DESCRIPTION

10.1 COMMUNICATION ERROR

If the communication error ("ER ---") appears, make sure that the plug has a good contact with the current and 
reset  the  system  by  unplugging  the  equipment  from  the  power  supply,  wait  at  least  60  seconds  before 
reconnecting.

If the error continues, contact your Emaux technical ser vice.

10.2 OPERATION ERRORS

When the controller is not working, an error code will be shown on the controller display. E.g. “Er : OV”. Press the 

“Start/Stop” button to restore the controller.

The common error codes are the following:

Error

Description

Reason

OC

Overcurrent: driver current output exceeds the threshold 
(200% of rated 

Over voltage:  the  main  circuit  DC  voltage  exceeds  the 
threshold.

OV

UV

Under-voltage: the main electric current is too low.

OH

Overheating: the motor heat sink is overheated.

Driver output failure

Driver IPM module is damaged


Power supply voltage exceeds the control settings

Exceeded power from the power supply

Ambient temperature is too high

Supply voltage fluctuation is too large

Ambient temperature is too high

Motor Cooling Fan does not work

Summary of Contents for SPV Series

Page 1: ...MANUAL SUPER POWER VARIABLE SPEED PUMP With Wi Fi AND MODBUS OPTIONS NSF only apply for NSF version Model SPV Series SAA STRIVE FOR CLEAR WATER www emauxgroup com EMAUX WATER TECHNOLOGY CO LTD EMPU210...

Page 2: ...mmary of Emaux Claim Process in 3 steps 1 Claim Customer contacts Emaux salesperson and provides completed details of the claim which includes 1 Information about the failed product such as the part n...

Page 3: ...erate under high pressure When any part of the circulating system i e lock ring pump filter valves etc is serviced air can enter the system and become pressurized Filter tank Lid and pre filter cover...

Page 4: ...Entrapment or entanglement hair is pulled into and or wrapped around the grate of the drain cover 4 Mechanical Entrapment the bather s jewelry or clothing gets caught in the drain or the grate 5 Evisc...

Page 5: ...ure 2 Place the pump as close to the water source as possible so that the suction pipe is short straight and direct to reduce the friction loss Don t install the pump at more than 10ft 3 meters of geo...

Page 6: ...Running speed and power rating display 3 Pre set Speed 3 pre set running speeds 4 Function settings Real time clock 3 pre set speeds 2 schedule settings NO flow self priming settings 5 Error display O...

Page 7: ...re Version Su00x Reset RESET Title Value Operation Light Start Stop Increase Page Up Decrease Page Down Mode Setting Preset Speed 1 Preset Speed 2 Preset Speed 3 Quick Setting Quick Setting Quick Sett...

Page 8: ...ble and disable switch at the end of each setting to turn it ON or OFF 5 Freeze protection default temperature is 4 degree C in 4 or 8 hours running in setting speed 6 To do any change touch save to s...

Page 9: ...ect connection is a ONE To ONE connection without access Home Network It is just like a private controller It can be connected and control by mobile phone tablet PC laptop top or any Wi Fi enable devi...

Page 10: ...r details and all lights will start flashing Press Run shortly at the error menu to auto recover the variable speed driver keep the driver Off 10 ERRORS DESCRIPTION 10 1 COMMUNICATION ERROR If the com...

Page 11: ...other When there is an error the variable speed driver will restore the settings to those before the error The priority setting is still applicable P13 SYSTEM RESET TO FACTORY DEFAULT SETTING 7 SYSTE...

Page 12: ...ation interface for external automation controller It is not for domestic user access purpose It is an always ready to interface for external automation control The pin assignment is 1 A and 2 B The w...

Reviews: