42
SBC session border controllers
–
Firmware versions file
— firmware version file name. The name mast have '.manifest' extension with maxi-
mum length of 64 characters;
–
Firmware upgrade interval, min —
the interval at which the server is checked for new firmware.
Upload configuration
SBC can automatically upload the configuration to an external FTP/TFTP server whenever it is saved to non-
volatile memory.
–
Enable autoupload
— enables the configuration upload function;
–
Protocol
— select a protocol according to which the upload will be performed. FTP or TFTP is supported;
–
Server
— the IP address of the server to which the upload will be made;
–
Port
— the server port to which the upload will be made;
–
Path to file
— the directory on the server where the configuration will be saved;
–
Username
— the name for authentication when using the FTP protocol;
–
Password
— the password for authentication when using the FTP protocol.
Monitoring
4.1.2.1
Telemetry
This section contains information on the device telemetric sensor readings as well as the information on
power supplies and fans installed.
Monitoring –> Telemetry
Temperature sensors
For SBC-1000:
–
TempSensor #0
— CPU temperature;
–
TempSensor #1
— switch temperature.
For SBC-2000:
–
CPU temperature
— temperature of the processor.
Power supply
–
Power module #0 —
the status of the power supply in the zero posi-
tion;
–
Power module #1 —
the status of the power supply in the first posi-
tion.