background image

   

 

- 9 - 

sure to setup the related configurations as described in 

Section 6.10 Network Setup

 

 

USB 2.0 disk drives, card reader, etc. 
If the user wants to use USB2.0 peripheral device to retrieve important recorded images and/or audio, please connect it to the 
USB port connector. 

 

 

I/R remote

 control

 

The user may use I/R remote control to control the digital video/audio recorder. 

 

 

PTZ Cameras 
Connect the  RS-485  connector to PTZ camera(s)  via the appropriate cable.  The system  supports a variety  of  different PTZ 
cameras, including Pelco D protocol Dome, SamSung SCC-641P, etc. But different PTZ cameras can coexist in a system only 
if they support the same protocol. Please make sure to set the PTZ  ID of the camera(s), and setup the camera (RS-422/485 
(

Section 6.9

) accordingly.

 

       
 

4. Main Screen And Basic Operations 

 

 

 

The split-window screen, as shown above, is the  main screen after system startup. There are two types of split-window screens, 
including 1-Window and 4-Window. The system will remember the last one before normal shutdown (as described in 

Section 5.6

of  the  system.  In  addition  to  the  split  windows,  the  system  time  is  displayed  on  the  lower-left  corner,  the  system  states  on  the 
lower-right corner, and the rolling screen messages, if shown while certain event occurs, on the lower corner.   

 

The system states, from right to left, are described as the followings: 

 

(1) Normal recording percentage, 
(2) Alarm recording percentage, 
(3) Mute state – speaker icon shown for 

unmute

, not shown for mute, 

(4) X2 state – X1, X2, or X4, 
(5) Manual record ON/OFF – REC icon shown for ON, 
(6) Backup state – Backup icon shown for backup,   
(7) SEQ display ON/OFF or playback state – SEQ icon shown for SEQ display ON, other icons for different playback states. 

 

4.1 Text Input

 

(Please match with a remote control usage)

 

 

There are certain circumstances that the system requires the user to enter text, such as system login, camera title setup, and so on. 
Please follow the steps below to enter text: 

 

(1) Press 

ENTER

 to edit the highlighted option. The flashing cursor will be shown to indicate the editing point. Besides, a 

keypad 

hint

 will be shown as below.

 

 

 

 

(2) Press 

◄►

 

to move the cursor to the left/right. 

 

(3) Press 

code

 in text editing mode to change text case. (If this entry can accept number only, pressing 

code

 will have no effects.) 

Indicators on the screen show the current setting: 

123

 = Number only 

abc

 = No capital letters 

ABC

 = All capital letters 

CODE

 = Internal code for the selected language, such as Chinese, Japanese, etc. 

 

(4) Press a number key (

1-9, 0)

 repeatedly until the character you want appears. (

1

 for 1 or space, 

2

 for 2, a/A, b/B, or c/C,

 

 

for 5, j/J, k/K, l/L

MUTE 

for 6, m/M, n/N, o/O, the others as shown on the 

keypad hint

) If internal 

CODE

 is selected, a 

CODE line will be added (after the first code is entered) for each new code to be entered. Please check the internal code table 
for the selected language. For 2-byte code, e.g. Chinese or Japanese, the code accepted is from 0000 - FFFF. 

36% 

   

 

- 10 - 

 

(5)  Press 

mark

  to  bring  up  a  list  of  punctuation  marks  and  special  characters.  The  highlighted  character  in  the  list  shows  the 

selected one. Press 

▼◄►

 

to change the selection. 

(6) If you make a mistake, press 

BS

 to remove the character to the left of the cursor, or press 

DEL

 to delete the character at the 

current cursor position. 

 

(7)  In  text  editing  mode,  internal  code  box,  and  mark  list,  press 

ENTER

  to  exit  and  save  changes,  press 

ESC

  to  exit  without 

making changes.

 

 

4.2 Login And Logout 

 

There are three password levels in the system, including Administrator (highest), Supervisor, and Operator (lowest). If the user 
does not login the system, he/she will be treated as “Guest” and can only view live video display. 

 

The system allows up to 18 user accounts. The administrator can set up the login name and password for each user. (Please refer to 

Section 6.7

 for Password Setup.)   

The Operator can operate live video display, the Supervisor live video display, image playback and archive, and the Administrator 
everything. 

 

To login/logout the system, press 

MENU 

  in split-window display 

to 

call  up  Menu  display,  and  then  press 

ENTER

  when  the 

highlighted option is Login/Logout to enter Login/Logout display 

as 

shown. 

 

In  Login/Logout  display,  follow  the Text  Input  method described 

in 

Section 4.1

 to enter the Login name and Password, press 

 

to 

highlight and select Login option, and then press 

ENTER

 to login 

the 

system. If the user wants to logout the system, just press 

 

to 

highlight and select Logout option, and then press 

ENTER

. Press 

ESC

 to exit without making changes. 

 

There is one factory-preset login name/password aa/11 at Administrator level. The user can use it to login the system for the first 
time. 

 

Should the user have forgotten all the administrator-level passwords, please contact the local dealer or installer to recover 
from it. 

 

4.3 Basic Operations 

 

The basic user’s operations after he/she has logged into the system are described below: 

 

 

Numeric

 

Press these buttons to switch to the full-window display for the camera. 

 

 

Alarm Reset

 

Press this button to cancel alarm activation, i.e. reset the alarm outputs and silence the buzzer. 

 

 

MODE (Administrator/Supervisor)

 

In  split-window  display,  press  this  button  to  change  circularly  the  live/playback  mode  for  the  focus  window  and  the  other 
windows that form a rectangle on the screen. 

 

 

SEQ

 

Press  this  button  to  switch  to  or  return  from  SEQ  display  mode.  In  SEQ  display  mode,  each  page  in  the  sequence  will  be 
shown for the preset page dwelling time sequentially, and SEQ icon will be shown on the lower-right corner of the screen. 

 

 

SEARCH (Administrator/Supervisor)

 

In split-window display, press this button to display the search menus. The system will remember the last one the user chose. 

 

 

REC

 

Press this button to force manual recording. To stop manual recording, press it again. All cameras will be recorded as if the 
scheduled record is A/V, and REC icon will be shown on the lower-right corner of the screen if manual recording is ON. 

 

 

MENU / ESC

 

In split-window display, press this button to display the versatile menu. 

 
 

 

Stop (

) / PTZ

 

In split-window display, press this button to enter PTZ control mode if the focus camera is a PTZ camera. 

 

 

X2

 

In full screen display, press this button to enter Digital Zoom mode. Please refer to 

Section 4.4 Digital Zoom

 for the detailed 

operations in Digital Zoom mode. 

 

 

▼◄►

 

Press these buttons to move focus. The title of the camera for the focus window is highlighted as shown on the screen. 

Summary of Contents for DVR154S

Page 1: ...Performance and lifetime of hard disk drives are easily affected by heat used at high temperature It is recommended to use this appliance at temperature within 20o C 30o C 68o F 86o F Handle the hard...

Page 2: ...combination of a hard disk recorder a video multiplexer and a web server To achieve the highest inter connectivity and inter operability this series of digital video audio recorders are all based on i...

Page 3: ......

Page 4: ......

Page 5: ...selection 6 If you make a mistake press BS to remove the character to the left of the cursor or press DEL to delete the character at the current cursor position 7 In text editing mode internal code b...

Page 6: ......

Page 7: ...D device and then press ENTER to command the system to connect with it If the device is already connected eg R W Read write as shown in Current Status please press ENTER to command the system software...

Page 8: ...Menu display and return to Menu display If the user wants to reset all the settings to factory default values he she may press to change the highlighted option to Factory Defaults and then press ENTER...

Page 9: ...0 CIF 60 Half D1 30 Full D1 PAL 100 CIF 50 Half D1 25 Full D1 or the system will lower the actual rate automatically at recording Normal Record IPS the normal record IPS for this camera This camera wi...

Page 10: ...e the sensitivity from 10 1 for the motion detection of this camera CALL Press this button to increase the sensitivity from 1 10 for the motion detection of this camera SEARCH Press this button to tes...

Page 11: ...o change the camera for the current page Press these buttons to change the current page for this SEQ Display Type ESC Press this button to escape from Display Page Setup and return to SEQ Display Setu...

Page 12: ...e formatting the HDD The general operations are as follows MODE Format Press this button to format the HDD A confirmation dialog will be shown on the screen press ENTER to confirm or ESC to 24 cancel...

Page 13: ...format used for the system time displayed on the lower left corner of the main screen Press buttons to select the desired format Language press buttons to select the language for the system The langu...

Page 14: ...follows Press these buttons to select the items ESC Press this button to escape from this screen and return to Network Setup display If the Save dialog is shown press ENTER to exit and save ESC to exi...

Page 15: ...ch Playback Archive Administrator Supervisor There are three ways to search the recorded video audio for playback a Search by time b Search by event c Search archived files In split window display pre...

Page 16: ...is a brief description for each item and its specific operations Backup Device press ENTER to call up Backup Device dialog if there s no Backup device connected Disk Storage to select the disk storag...

Page 17: ...this unit through web browser please make sure the followings For most PCs only step 3 6 is needed 1 This unit is connected to the network correctly and the configurations are all setup correctly Plea...

Page 18: ...vent logs Click on Refresh Up or Down to update the event logs Click on the desired event log to highlight and select it Click on the OK button to search the recorded video audio for the highlighted e...

Page 19: ...hen double click on Setup exe in the CD to install and Utilities Setup exe to install the utility programs Please follow the instructions on the screen to install the software in the default directory...

Page 20: ...face reference When you make use of the mouse operation the DVR please move the cursor to screen below you will see the icons of mouse function displayed pressing the diagram mark to hint an operation...

Page 21: ...n setup via keypad I R remote control Remote Setup upload via Windows application software 42 Multi lingual Yes Reliability System recovery Auto power on after power loss recovery Timer Built in real...

Page 22: ...88 176 265 529 6 18 4 101 201 302 604 5 14 0 132 265 397 794 4 11 3 164 328 492 983 3 7 7 241 481 722 1443 2 5 6 331 661 992 1984 1 3 6 514 1029 1543 3086 720x240 9 16 1 58 115 230 345 690 Half D1 8 1...

Page 23: ...889 1778 2778 5556 2 2 2 292 585 1170 2339 3655 7310 1 1 4 463 926 1852 3704 5787 11574 Average Picture Size is estimated based on typical camera scene and averaged by H 264 I P P frames NOTE Above s...

Reviews: