Manual: R1300-X-00-X_EN Release: 1.04 © Elotech GmbH Page 18/20
Display
Parameter
Display "Set"
"Process"
The range of adjustment is dependant on the sensor and the alarm configuration.
Both have to be set in the configuration level.
AL 3
Alarm 3,
Out3
signal contact, setpoint dependent
OFF; -999...1000
units
(ex works)
OFF; -99,9...100,0
1)
OFF; -9,99...10,00
2)
limit comparator, setpoint dependent
OFF; 1...1000
units
(ex works)
OFF; 0,1...100,0
1)
OFF; 0,01...10,00
2)
limit contact, process value dependent
OFF; range bottom ... range top
Alarm 2 is only available, if the controller is programmed as a 2-point- or a continuous-controller
in the configuration-level.
AL 2
Alarm 2,
Out2
signal contact, setpoint dependent
OFF; -999...1000
units
(ex works)
OFF; -99,9...100,0
1)
OFF; -9,99...10,00
2)
limit comparator, setpoint dependent
OFF; 1...1000
units
(ex works)
OFF; 0,1...100,0
1)
OFF; 0,01...10,00
2)
limit contact, process value dependent
OFF; range bottom ... range top
The following parameter is only shown, if the controller is configurated as a 3-point-step-controller.
Hand manual mode
OFF:
The instrument is operating like a controller
(ex works)
On :
The instrument operates only as an actuator
„On“:
Display „process“ : the actual process value is displayed.
Display „set“
: the word
Hand
will be displayed, instead of the setpoint.
Press key „ up „:
OUT1 (on) is activated
Press key „down“:
OUT2 (off) is activated
The next parameter is now the setpoint 1 (SP1).
It has no influence, although it can be preadjusted for later application.