Tuba Installation Guide
Technical Specifications
MAN-TUBIG (Ver. 1.503)
72
4.9.7.
Potentiometer
Feature
Details
Potentiometer Format
Single-ended
Operating Voltage Range
0 to 5 V supplied by the Tuba
Potentiometer Resistance
100
Ω
to 1 k
Ω
… above this range, linearity
may be affected detrimentally
Input Resistance
100 k
Ω
Resolution
14 Bit
4.9.8.
Encoder Outputs
Feature
Details
Encoder output format
•
A, B, Index
•
Differential outputs
•
Quadrature
Interface
RS-422
Port B1 output current capability
•
Driving differential loads of 200
Ω
on
INDEX/INDEX-, CHB/CHB- and CHA/CHA-
pairs
Port B2 output current capability
•
INDEXO/INDEXO-, CHBO/CHBO- and
CHAO/CHAO- pairs are not loaded
Available as options
•
Two simultaneous buffered outputs of
main- incremental encoder input
•
Two simultaneous emulated encoder
outputs of the analog encoder input
•
Two simultaneous emulated encoder
outputs of the resolver input
•
Two simultaneous emulated encoder
outputs of the Tachometer Input
•
Two simultaneous emulated encoder
outputs of the Potentiometer Input
•
Buffered output of auxiliary input
Maximum frequency
f
MAX
: 5 MHz pulses/output
Index (marker)
Length of pulse is one quadrature (one
quarter of an encoder cycle) and synchronized
to A&B