![Elmo TUB Series Installation Manual Download Page 66](http://html1.mh-extra.com/html/elmo/tub-series/tub-series_installation-manual_2394819066.webp)
Tuba Installation Guide
Technical Specifications
MAN-TUBIG (Ver. 1.503)
65
4.5.
Power Ratings
Feature
Units 12/230 15/230 20/230 12/460
15/460
20/460
Minimum supply voltage
VAC
60
140
Nominal supply voltage
VAC
1 x 115, 1 x 230, 3 x 230
3 x 400, 3 x 460
Maximum supply voltage
VAC
1 x 270 or 3 x 270
3 x 505
Maximum continuous power
output
W
3600
4500
6000
6800
8500
11300
Efficiency at rated power (at
nominal conditions)
%
> 93
Auxiliary supply voltage `
VDC
24 ± 15%
Auxiliary power supply
VA
20
Amplitude sinusoidal/DC
continuous current
A
12
15
20
12
15
20
Sinusoidal continuous RMS
current limit (Ic)
A
8.5
10.6
14.1
8.5
10.6
14.1
Peak current limit
A
2 x Ic
Built-in shunt (peak power)
kW
6
11
Weight
kg (lbs)
2.7 kg (5.9 lbs)
Dimensions
mm
(in)
247 x 190 x 92 (9.7" x 7.5" x 3.6")
Digital in/Digital out/Analog
in
10/6/2
Mounting method
Wall mount (“Bookshelf”) or DIN rail
4.6.
Environmental Conditions
Feature
Details
Operating ambient temperature
according to IEC60068-2-2
0 °C to 40 °C (32 °F to 104 °F)
Storage temperature
-20 °C to +85 °C ( -4 °F to +185 °F)
Maximum non-condensing humidity
according to IEC60068-2-78
95%
Maximum Operating Altitude
2,000 m (6562 feet)
Mechanical Shock
according to IEC60068-2-27
15g / 11ms Half Sine
Vibration
according to IEC60068-2-6
5 Hz ≤ f ≤ 10 Hz: ±10mm
10 Hz ≤ f ≤ 57 Hz: 4G
57 Hz ≤ f ≤ 500 Hz:5G