35
If more than 17 incorrect keys entered,
then the unit will revert to normal
Alarm On mode.
Once the System Reset is executed,
all the programmed data are returned
to its default value and all the devices
having been learnt-in are removed.
You have to do the programming and
learn in the device one by one again.
9.2. CID Event Code
The message composition for CID Event code
is in the form:
ACCT MT QXYZ GG C
1
C
2
C
3
And is explained in the following table:
Where
ACCT
= 4 Digit Account number (0-9, B-F)
MT
= Message Type, 18H.
Q
= Event qualifier, which gives specific
event information:
XYZ
= Event code (3 Hex digits 0-9, B-F)
GG
= Group or Partition number (00H)
C
1
C
2
C
3
= Zone
C
1
C
2
C
3
= Zone number
001 Zone 1
002 Zone 2
…………………..
080 Zone 80
100 - Medical
When a Medical Alarm is triggered by
WTR, KP or Panel.
110 - Fire
When a fire alarm is triggered by the
KP or Panel.
111 - Smoke
When the Smoke Detector (SD) is
triggered.
120 - Panic
When triggered by the KP, Panel, RC
or PB.
130 - Burglary
When DC, IR set as Burglar attribute
is triggered
Any Tamper violation under Away Arm
mode
131 - Perimeter
When DC, IR set at Entry attribute is
triggered.
132 - Interior
When DC, IR set at Home Omit
attribute is triggered.
137 - Panel Tamper / Panel Tamper
Restore
When the panel’s Tamper is violated.
When the panel’s Tamper is restored.
147 - Sensor Supervisor Failure / Sensor
Supervision Restore
When the panel is unable to receive
the signal transmitted from any device
individually for 24 Hours.
When panel receives signal from
supervision failure sensor again.
154 - Water leakage / Restore
When the Water Sensor is triggered.
When the Water Sensor is restored.
158 - High Temperature / Restore
When the temperature exceeds High
Temperature setting.
When the above is restored
159 - Low Temperature / Restore
When the temperature drops below
Low Temperature setting.
When the above situation is restored
162 - CO detector
301 - AC Failure/ AC Power Restore
When the AC power fails for more
than 10 sec.
Restore from AC power failure
344 - Interference / Interference Restore
383 - Sensor Tamper / Sensor Tamper
Restore