21
Contact and PIR sensor only. For
other devices, the value will have no
effect, you can enter any of the values
from 0, 1, 2.
<
<
E
E
X
X
A
A
M
M
P
P
L
L
E
E
:
:
>
>
To set the device in Zone 1 to Burglar attribute,
and device name : Kitchen, the SMS command
will be:
PROG 1234 DEVE:1,0,Kitchen
Inquire Device Setting:
Sending this command will order the Control
Panel to report back its current device setting.
SMS Command: DEV?
Parameter : 1~6
1: Inquire devices in Zone 1~5
2: Inquire devices in Zone 6~10
3: Inquire devices in Zone 11~15
4: Inquire devices in Zone 16~20
5: Inquire devices in Zone 21~25
6: Inquire devices in Zone 26~30
<
<
E
E
X
X
A
A
M
M
P
P
L
L
E
E
:
:
>
>
To inquire the current device setting in Zone
6~10, the SMS command will be:
PROG 1234 DEV?:2
The Control Panel will send back a SMS
message in the following format:
Parameter 1: 1~6
1: For devices in Zone 1~5
2: For devices in Zone 6~10
3: For devices in Zone 11~15
4: For devices in Zone 16~20
5: For devices in Zone 21~25
6: For devices in Zone 26~30
Parameter 2: 6 (Fixed value)
Parameter 3: (Zone number)
Parameter 4: 0~24 (Device Type)
0: Remote Control
1: Door Contact
3: PIR Sensor
4: Smoke Sensor
7: Remote Keypad
10:Wrist Transmitter
11:Water Sensor
16:Night Switch
17:Panic Button
19:Carbon Monoxide Detector
20:Temperature Sensor
21:BX
22:Remote Keypad
23:DC
24:EIR Sensor
25:SR
26:Repeater
Parameter 5: 0~2(Device Attribute)
For Door Contact/ PIR Sensor/
EIR Sensor
0: Burglar
1: Home Omit
2: Entry
For other sensors: 0
Parameter 6: (Device Name)
Parameter 3~6 are repeated for different zone
numbers and separated by parenthesis. Empty
zones will be left blank.
<
<
E
E
X
X
A
A
M
M
P
P
L
L
E
E
:
:
>
>
If the current Zone 6-10 settings are as follow:
Zone 6: Door Contact, Entry, Name: Front Door
Zone 7: PIR Sensor: Home Omit, Name:
Kitchen
Zone 8~10: Empty
The SMS response message will be:
DEV?:2,6,(6,1,2,Kitchen),(7,3,1,Front
Door),(8,,,),(9,,,),(10,,,)
Delete Device
To remove a device from the system:
SMS Command: DEVD
Parameter 1: 1~30 (Device Zone Number)
<
<
E
E
X
X
A
A
M
M
P
P
L
L
E
E
:
:
>
>
To remove the device at Zone 3, the SMS
command will be:
PROG 1234 DEVD:3