© 27.04.2005 ELKA-Torantriebe GmbH u. Co. Betriebs KG                     Page 11  

                                   EST 4004K 

 

LT

LT

LT

LT

LT

BT

BT

BT

BT

BT

BT

BTG

BTG

BTG

BTG

LT

Funk

Funk

Funk

running time 

is stored

all personal 

codes are 

erased

position for 

partial opening 

is stored

remote code 

for BA1 is 

stored

time to stay for 

position open 

is stored

press 3s
Diag-LED lights

Diag-LED flashes
quickly

Diag-LED lights,
gate opens and
closes, 10 s
reserve are set
Diag flashes

Diag-LED

flashes each 
second, set

new reserve

Diag-LED
lights

Diag-LED
lights, BTG is 
deadman
button, move

to partial open 

position

gate closes

Diag-LED
lights for 3s

Diag-LED

flashes each 
second, set
time to stay
open

Diag-LED flashes
quickly

Diag-LED flashes
quickly

Diag-LED
lights for 3s

Diag-LED
lights for 3s

Diag-LED

flashes each 
second, set
time to stay
open

remote code 

for BT is 

stored

time to stay for 

partial open is 

stored

remote code 

for BTG is 

stored

7.3. Programming 

 
The minimum to ensure that the opener works correctly is that the running time must be learned. Other 
things like automatic closure, or time which the gate should stay open before closing can also be set during 
programming. 

 

The following settings can be altered if required: 
Time required to open (running time) 

 

 

 

 

(0...150 s, 

default 30 s) 

Reserve for the running time 

 

 

 

 

 

(0...10 s, 

default 10 s) 

Time to stay open before automatic closure 

 

 

 

(0...300 s, 

default 20 s) 

Time to stay open before automatic closure from partial position  

(0...300 s, 

default 20 s) 

Position for partial opening for pedestrians 

 

 

 

(any position,  default half way) 

Remote control codes for BT, BTG and BA1 

 

 

 

 

 

(default BT -+-+...) 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 

Learning the time for opening (running time) and reserve

 

Press LERN until the LED DIAG lights (approx. 3 seconds). 
Press LERN twice. 
The gate closes from any position, opens completely and closes again. The time required and the power 
selected (DIP A1 and DIP A2) are then saved. The LED DIAG starts flashing quickly, the running time is 
learned. Press LERN if you want to accept the default value for the running time reserve (10 s). The 
controller is ready for use. 
If you want to change the running time reserve press BT, the LED DIAG flashes in 1 second intervals, press 
BT when the required time has elapsed. The controller is ready for use. 
The position for partial opening is automatically set to half way when the running time is learned, this means 
that any other value for pedestrian opening must be learned after the running time! 

 
Learning partial opening for pedestrians

 

Press LERN until the LED DIAG lights (approx. 3 seconds). 
Press

 

LERN once. The LED DIAG flashes quickly. 

The BTG button moves the gate in dead mans mode. When the gate is at the required position press LERN. 
The gate closes automatically and the information is stored. The controller is ready for use. 

 

Learning the time to stay open before automatic closure (completely open)

 

Press LERN until the LED DIAG lights (approx. 3 seconds). 
Press BT twice. The LED DIAG flashes in 1 second intervals. 
When the time required has elapsed press BT again. 
The time is stored and the controller is ready for use. The time is only effective when automatic closure is on 
(DIP A6 ON). 

 

Learning the time to stay open before automatic closure (partial opening for pedestrians)

 

Press LERN until the LED DIAG lights (approx. 3 seconds). 
Press BTG twice. The LED DIAG flashes in 1 second intervals. 
When the time required has elapsed press BTG again. 
The time is stored and the controller is ready for use. The time is only effective when automatic closure is on 
(DIP A5 ON). 

 

Summary of Contents for EST 4004K

Page 1: ...ST 4004K Contents Page 1 Usage 2 2 Technical data 2 3 Measurements 2 4 Installation 3 4 1 Emergency release 4 5 Electrical connections 4 6 Connection example 5 7 MO 44 2 Controller 6 7 1 Connections 7...

Page 2: ...ply 400 Vac 50 Hz Power consumption 2 2 kW Control box MO44 2 Electronic brake no The MO 44 2 control box has among others the following characteristics Safety Four separate reactions to the photo cel...

Page 3: ...on parallel to the gate at a distance of 60 mm Mark the middle of each hole on the foundation e Fix the opener either with plugs and screws M20 or with heavy duty tie bolts e Decide at what height the...

Page 4: ...ose the gate and push the holding plate with magnet along the rack until the LED SEZ turns off Fix the holder at this point on the rack so that the magnet passes the housing at a distance of about 10...

Page 5: ...27 04 2005 ELKA Torantriebe GmbH u Co Betriebs KG Page 5 EST 4004K 6 Connection example...

Page 6: ...27 04 2005 ELKA Torantriebe GmbH u Co Betriebs KG Page 6 EST 4004K 2T1 1L1 1L1 2T1 14NO 6T3 4T2 A2 13NO 5L3 3L2 K2 A1 6T3 4T2 14NO A2 5L3 3L2 K1 13NO A1 loop BA1 STOP START 7 MO 44 2 Controller...

Page 7: ...itted to terminal EXT AUF The LED BA lights if BA1 or the corresponding remote button is pressed A permanent open signal is possible BA2 Button to open the gate n o the signal is valid only for this c...

Page 8: ...tputs 300 mA LS TST Power supply for transmitter The controller switches the 24 Vdc on terminal LS TST off 7 2 Operating mode Motor power Changes only take effect if the running time is then learned a...

Page 9: ...when the gate is open The gate reopens if BT is pressed during closing Warning prior to opening DIP B1 OFF No warning DIP B1 ON The warning light is switched on 4 seconds before the gate opens Warnin...

Page 10: ...e relay connections of the receivers have to be connected in series Parallel to the relay connections a resistor of 1kOhm 5 each has to be connected The photo cell test consists of two parts The trans...

Page 11: ...N until the LED DIAG lights approx 3 seconds Press LERN twice The gate closes from any position opens completely and closes again The time required and the power selected DIP A1 and DIP A2 are then sa...

Page 12: ...The LED DIAG stays on as long as a signal is received Release the button The code is stored and the controller is ready for use 8 Timer card optional The 7 day timer can switch between day and night...

Page 13: ...DIAG 11 flashes The controller has detected a fault in the redundant detection of BS stop contact The controller is faulty DIAG 12 flashes The controller detects that the TRIAC or one of motor relays...

Page 14: ...e GmbH Co Betriebs KG accepts no liability for damage which is caused by using the appliance for purposes other than those for which it is built ELKA Torantriebe GmbH Co Betriebs KG cannot recognise e...

Reviews: