background image

© 27.04.2005 ELKA-Torantriebe GmbH u. Co. Betriebs KG                     Page 2  

                                   EST 4004K 

 

1. Usage 

For horizontal moving sliding gates either on rails or as a cantilever, up to the weights stated in the technical 
data. Please take note of the valid safety regulations. 

 

2. Technical 

Data 

 

 

EST 4004K 

Maximum weight 

4000 kg 

Recommended maximum length 

16 m 

Self blocking at open and closed positions 

yes 

Approximate speed 

0.18 m/s 

Rack Module 

Duty cycle 

75% 

Temperature range 

-20°C to +70°C 

Emergency release 

yes 

Possible height adjustment 

30 mm 

Housing H x W x L 

800x372x270 mm

Opener weight 

68,0 kg 

Power supply 

400 Vac / 50 Hz 

Power consumption 

2.2 kW 

Control box 

MO44-2 

Electronic brake 

no 

 

The MO 44-2 control box has among others the following characteristics: 
 
Safety:   

Four separate reactions to the photo-cell. 
Automatic test of the photo-cells before each gate movement can be enabled. 
Integrated evaluator for safety contact strips with 8.2 k

 terminating resistors. 

 
Actions: 

Partial opening (e.g. for pedestrians) can be programmed for any position. 
Automatic closure can be set separately for completely open and for partially open. 
A dead man’s button can also be set. 
Separate inputs for OPEN, STOP and CLOSE commands. 
The OPEN button can also be transmitted to a further control box (e.g. for a barrier). 
Optional timer card for automatic switching between day and night operation. 

 

3. Measurements 

 

 

Summary of Contents for EST 4004K

Page 1: ...ST 4004K Contents Page 1 Usage 2 2 Technical data 2 3 Measurements 2 4 Installation 3 4 1 Emergency release 4 5 Electrical connections 4 6 Connection example 5 7 MO 44 2 Controller 6 7 1 Connections 7...

Page 2: ...ply 400 Vac 50 Hz Power consumption 2 2 kW Control box MO44 2 Electronic brake no The MO 44 2 control box has among others the following characteristics Safety Four separate reactions to the photo cel...

Page 3: ...on parallel to the gate at a distance of 60 mm Mark the middle of each hole on the foundation e Fix the opener either with plugs and screws M20 or with heavy duty tie bolts e Decide at what height the...

Page 4: ...ose the gate and push the holding plate with magnet along the rack until the LED SEZ turns off Fix the holder at this point on the rack so that the magnet passes the housing at a distance of about 10...

Page 5: ...27 04 2005 ELKA Torantriebe GmbH u Co Betriebs KG Page 5 EST 4004K 6 Connection example...

Page 6: ...27 04 2005 ELKA Torantriebe GmbH u Co Betriebs KG Page 6 EST 4004K 2T1 1L1 1L1 2T1 14NO 6T3 4T2 A2 13NO 5L3 3L2 K2 A1 6T3 4T2 14NO A2 5L3 3L2 K1 13NO A1 loop BA1 STOP START 7 MO 44 2 Controller...

Page 7: ...itted to terminal EXT AUF The LED BA lights if BA1 or the corresponding remote button is pressed A permanent open signal is possible BA2 Button to open the gate n o the signal is valid only for this c...

Page 8: ...tputs 300 mA LS TST Power supply for transmitter The controller switches the 24 Vdc on terminal LS TST off 7 2 Operating mode Motor power Changes only take effect if the running time is then learned a...

Page 9: ...when the gate is open The gate reopens if BT is pressed during closing Warning prior to opening DIP B1 OFF No warning DIP B1 ON The warning light is switched on 4 seconds before the gate opens Warnin...

Page 10: ...e relay connections of the receivers have to be connected in series Parallel to the relay connections a resistor of 1kOhm 5 each has to be connected The photo cell test consists of two parts The trans...

Page 11: ...N until the LED DIAG lights approx 3 seconds Press LERN twice The gate closes from any position opens completely and closes again The time required and the power selected DIP A1 and DIP A2 are then sa...

Page 12: ...The LED DIAG stays on as long as a signal is received Release the button The code is stored and the controller is ready for use 8 Timer card optional The 7 day timer can switch between day and night...

Page 13: ...DIAG 11 flashes The controller has detected a fault in the redundant detection of BS stop contact The controller is faulty DIAG 12 flashes The controller detects that the TRIAC or one of motor relays...

Page 14: ...e GmbH Co Betriebs KG accepts no liability for damage which is caused by using the appliance for purposes other than those for which it is built ELKA Torantriebe GmbH Co Betriebs KG cannot recognise e...

Reviews: