CFW-08 - QUICK PARAMETER REFERENCE
According to
the inverter
model
According to
the inverter
Parameter
Function
Adjustable Range
Factory
Unit
User
Page
Setting
Setting
Notes found on the Quick Parameter Reference:
(1)
This parameter is only displayed in vector mode (P202 = 2).
(2)
This parameter is only displayed in scalar mode P202 = 0 or 1.
(3)
This parameter can be changed only when the inverter is disabled (stopped motor).
(4)
This parameter is only available with HMI-CFW08-RS.
(5)
The analog input value is represented by zero when it is not connected to an external signal.
In order to use an analog input as a digital input with NPN logic (P235 or P239 = 3), it is
necessary to connect a 10 k
resistor from terminal 7 to 6 (AI1) or 8 (AI2) of the control
terminal strip.
(6)
This parameter is only available in the CFW-08 Plus version.
(7)
The parameter value changes automatically when P203 = 1.
P407
(3)
Rated Motor Power
0.50 to 0.99
-
Factor
Measured Parameters
P408
(1) (3)
Run Self-Tuning
0 = No
0
-
1 = Yes
P409
(3)
Motor Stator Resistance
0.00 to 99.99
model
SPECIAL FUNCTION - P500 to P599
PID Regulator
P520
PID Proportional Gain
0.000 to 7.999
1.000
-
P521
PID Integral Gain
0.000 to 9.999
1.000
-
P522
PID Differential Gain
0.000 to 9.999
0.000
-
P525
Setpoint (Via Keypad) of the
0.00 to 100.0
0.00
%
PID Regulator
P526
Process Variable Filter
0.01 to 10.00
0.10
s
P527
PID Action
0 = Direct
0
-
1 = Reverse
P528
Process Variable
0.00 to 99.9
1.00
-
Scale Factor
P535
Wake up Band
0.00 to 100.00
1.00
%
P536
Automatic Setting of P525
0 = Active
0
-
1 = Inactive