10
CFW-08 - QUICK PARAMETER REFERENCE
Parameter
Function
Adjustable Range
Factory
Unit
User
Page
Setting
Setting
P236
Analog Input AI1 Offset
-999 to +999
0.0
%
P238
(6)
Analog Input AI2 Gain
0.00 to 9.99
1.00
-
P239
(3)(5)(6)
Analog Input AI2 Function
0 = (0 to 10) V/(0 to 20) mA/
0
-
(-10 to +10) V
(**)
1 = (4 to 20) mA
2 = DI6 PNP
3 = DI6 NPN
4 = DI6 TTL
5 = PTC
P240
(6)
Analog Input AI2 Offset
-999 to +999
0.0
%
P248
Analog Inputs Filter
0 to 200
10
ms
Time Constant
Analog Output
P251
(6)
Analog Output
0 = Output Frequency (Fs)
0
-
AO Function
1 = Input Reference (Fe)
2 = Output Current (Is)
3, 5, 8 = Not Used
4 = Motor Torque
6 = Process Variable (PID)
7 = Active Current
9 = PID Setpoint
P252
(6)
Analog Output AO Gain
0.00 to 9.99
1.00
-
P253
Analog Output AO Signal
0 = (0 to 10) V/(0 to 20) mA
0
-
1 = (4 to 20) mA
Digital Inputs
P263
(3)
Digital Input DI1 Function
0 = No Function or General
0
-
Enable
1 to 7 and 10 to 12 =
General Enable
8 = Forward Run
9 = Start/Stop
13 = FWD Run Using
Ramp 2
14 = On
P264
(3)
Digital Input DI2 Function
0 = Forward/Reverse
0
-
1 = Local/Remote
2 to 6 and 9 to 12 = Not Used
7 = Multispeed (MS2)
8 = Reverse
13 = REV Run - Ramp 2
14 = Off
P265
(3) (7)
Digital Input DI3 Function
0 = Forward/Reverse
10
-
1 = Local/Remote
2 = General Enable
3 = JOG
4 = No External Fault
5 = Increase E.P.
6 = Ramp 2
7 = Multispeed (MS1)
8 = No Function or
Start/Stop
9 = Start/Stop
10 = Reset
(**)
Only available on the control board A2 (refer to item 2.4). For programming instructions, please, refer to the parameter P235 detailed
description.