ELETTROQUADRI
SINCE 1983
Programming
4
© ELETTROQUADRI S.r.l.
30 / 66
INSTALLATION MANUAL
ENT/RST
Po
Option programming
Codes
Values
Meaning
Description
CS
no
disabled
CCS control
yes
active
dA
no
disabled
door pre-open
yes
enabled
Sd
no
disabled
use buttons C0 and C1 for up/down travel in
inspection mode
yes
enabled
br
no
disabled
block second attempt to open with floor button
yes
enabled
Go
no dot
disabled
gong operation
dot sn
in slowdown
RH dot
on stop
LH+RH dot on doors opening
LU
no dot
standard
light operation
dot sn
scheduled (with Km0(+) only)
RH dot
always on
CF
no
in slowdown
floor call cancellation mode
yes
on stop
rI
no
disabled
conditional return enable
yes
enabled
Cn
no
normal
motorized landing doors
yes
motorized
Ht
no
disabled
installation of Km0+ on car roof, using car serial
line in parallel with the duplex serial line
yes
enabled
CA
no
disabled
enable operation with code (keypad or RFID)
yes
enabled
ES
no
disabled
enable operation with energy save
yes
enabled
bA
no
disabled
block AUX when running
yes
enabled
GA
no dot
standard
AUX management
LH dot
intelligent
RH dot
blocked
Jo
no
disabled
monitor repeated releveling (yo-yoing)
yes
enabled
EP
no
disabled
enable door control EN_81_20_50
yes
enabled
Pn
00-15
see Table
chain jumper control protocol
nU
no
disabled
force parking at main floor when below
yes
enabled
MP3