ELETTROQUADRI
SINCE 1983
Programming
4
© ELETTROQUADRI S.r.l.
29 / 66
INSTALLATION MANUAL
ENT/RST
Po
Option programming
Codes
Values
Meaning
Description
FC
no
does not monitor
phase control
yes
monitors
Ac
dot sn
front door
self-retaining in door closure
RH dot
rear door
Ao
dot sn
front door
self-retaining in door opening
RH dot
rear door
do
1 to 4
number of floor backbones
floor call collection backbones
bu
0 to 7
level
volume of car/floor reserved confirmation beep.
Level 0 selects the electronic buzzer (no resonator)
SC
no
disabled
Car Call Cancel (collective only)
yes
active
Ar
no
disabled
stop with restart request
yes
enabled
rE
no
not permitted
restart after overtravel
yes
permitted
rC
no dot
never
restart after long travel timeout (max 2 consecutive
attempts)
dot sn
only after failure to start
RH dot
even with block in low speed
LH+RH dot always
PH
no
disabled
door control with manoeuvre buttons
yes
active
Cc
no
disabled
second appeal CCS open (recovery)
yes
active
rP
no
disabled
second appeal releveling
yes
active
2u
no
disabled
second down travel valve
yes
active
Cb
no
disabled
enables DCB button - disables time cut with car call
yes
active
nF
no
disabled
force parking on main floor
yes
active
bt
00
disabled
total block safety protocol (A3) (see table)
01-15
activates the protocol in
question
Pr
no
disabled
short floor manoeuvre (selective only)
yes
active
uL
no
disabled
microleveling
yes
active
MP3