SINUS K
INSTALLATION
INSTRUCTIONS
77/
191
20 CMA
0V for auxiliary analog input.
Control board zero
volt.
21 IREF
Input for main current reference
(0 20mA, 4÷20mA).
Rin: 100
Ω
Resolution: 10 bits
P19,
P20,
C29, C30:
(factory setting:
not used).
P19, P20,
C23, C24:
(factory setting:
not used).
22 CMA
0V for main current reference.
Control board zero
volt
24
MDOC
Open collector digital output
(collector terminal).
25 MDOE
Open collector digital output
(emitter terminal).
Open collector
NPN/PNP
Vmax: 48V
Imax: 50mA
P60:
(factory
setting: FREQ.
LEVEL), P63, P64,
P69, P70.
P60: (factory
setting: SPEED
LEVEL), P63,
P64, P69, P70,
P75, P76, P77.
26
RL1-NC
Multifunction digital relay output 1
(NC contact).
27
RL1-C
Multifunction digital relay output 1
(common).
28 RL1-NO
Multifunction digital relay output
(NO contact).
250 VAC, 3A
30 VDC, 3A
P61:
(factory
setting: INV O.K.
ON), P65, P66,
P71, P72.
P61: (factory
setting: INV O.K.
ON), P65, P66,
P71, P72, P75,
P76, P77.
29
RL2-C
Multifunction digital relay output 2
(common).
30
RL2-NO Multifunction digital relay output 2
(NO contact).
31 RL2-NC
Multifunction digital relay output 2
(NC contact).
250 VAC, 3A
30 VDC, 3A
P62:
(factory
setting: FREQ.
LEVEL), P67, P68,
P73, P74.
P62: (factory
setting: SPEED
LEVEL), P67, P68,
P73, P74, P75,
P76, P77.
Summary of Contents for SINUS K
Page 186: ...INSTALLATION SINUS K INSTRUCTIONS 186 191 15 DECLARATIONS OF CONFORMITY...
Page 187: ...SINUS K INSTALLATION INSTRUCTIONS 187 191...
Page 188: ...INSTALLATION SINUS K INSTRUCTIONS 188 191...
Page 189: ...SINUS K INSTALLATION INSTRUCTIONS 189 191...