SINUS K
INSTALLATION
INSTRUCTIONS
73/
191
The following links are required:
-
from control unit to driver board in inverter arm U (U fault signal)
-
from control unit to driver board in inverter arm V (V fault signal)
-
from control unit to driver board in inverter arm W (W fault signal)
-
from control unit to bus voltage detecting board installed on inverter arm U (VB signal)
N. 4 optical-fibre connections, 1mm, double standard plastics (0.22dB/m typical attenuation) with Agilent
HFBR-4516 connectors.
Figure 35: Double optical-fibre connector.
The following links are required:
-
from control unit to driver board in inverter arm U (top and bottom IGBT control signals)
-
from control unit to driver board in inverter arm V (top and bottom IGBT control signals)
-
from control unit to driver board in inverter arm W (top and bottom IGBT control signals)