background image

 

 

User Manual / NDA 100/3 TH(S) RG L30 230AC(PoE) LAN 

Meaning of the letter code: 

 

THS Sensor

 

 

Temperature and Humidity Sensor. 

52 or 40

 

 

Enclosure protection rating, IP 52 / IP 40. 

12DC/24DC/PoE

   

Power supply voltage. 

RS485/LAN/PoE 

Communication interface. 

 
 

3. Technical Specifications 

– LED Display  

 

The large-size LED display  consists of super-bright single color (version R) or  multi-

color (version RG) 7-segment LED modules with 100 mm digit height 

and 120° wide 

viewing angle. These parameters ensure excellent readability even from a far distance. 

Its  mechanical  construction  is  made  of  aesthetic  platinum  color  anodized  aluminium 

frame and gray tinted non-glare front glass. Back panel is made of steel, painted with 
black powder paint. Display

’s enclosure is suitable for use in indoor environment only. 

Flexible power supply cable for connecting to power mains is attached to back panel of 
display via cable gland. In case of product model with PoE interface, device is powered 
directly from PoE LAN.

 

 

Display Parameters 

 

• 

Number of viewing sides 

 

• 

Digit height  

 

100 mm 

 

• 

Format of digits  

 

88,8 °C + 88 %RH 

 

• 

Fixed units label    

°C (°F), %RH (%HR, %r.F.) as required. 

 

White letters on black background.

 

• 

LED elements  

 

Super-bright 7-segment LED modules,    

 

suitable for indoor light conditions,  
AlInGaP LED chips with long lifetime.

 

• 

LED color   

 

Red or multi-color Red/Green/Yellow.

 

Depends on product type ordered. 

• 

Readability range    

Up to 40 meters.

 

• 

Enclosure protection class   IP 30, indoor use only.

 

• 

Frame construction  

Anodized aluminium frame, steel back panel coated 

 

with black powder paint. 

 

• 

Frame color 

 

Platinum grey. 

• 

Front cover  

 

Non-glare PMMA glass, grey tinted, 3 mm thick. 

 

• 

Brightness control    

Automatic, depending on ambient light conditions, or 

 

direct control of brightness level set by user. 

 

• 

Power supply  

 

100-240 VAC, 50/60Hz, flexible power cord 2m.

 

• 

Data connections    

Depends on product type purchased: 

 

USB, RS485 (for data logging), RS485 (for external 
sensor), LAN, PoE 

• 

Dimensions  

 

470 x 350 x 59 mm  

• 

Weight  

 

 

4,4 kg  

• 

Operating temperature  

0°C to +50°C 

 

• 

Mounting    

 

Wall installation bracket included. 

 

Summary of Contents for NDA 100/3-2 TH RG L30 230AC PoE LAN

Page 1: ......

Page 2: ...tion depends on intended application Some applications require displaying temperature and humidity values without a need of logging measured values Other may require remote connection to a PC and data...

Page 3: ...duct model with PoE interface device is powered directly from PoE LAN Display Parameters Number of viewing sides 1 Digit height 100 mm Format of digits 88 8 C 88 RH Fixed units label C F RH HR r F as...

Page 4: ...more Relative humidity resolution 1 RH Connection version THS Internal plug in sensor 3 5 mm Jack connector sensor unit plugs into bottom side of display frame Connection version TH External wired se...

Page 5: ...l door plate The door plate is secured by two screws which must be removed first Once you remove the door plate attach the sensor cable connector into its corresponding PCB connector Then insert and s...

Page 6: ...5 NC LAN Vdc PoE 6 RX input 7 NC LAN Vdc PoE 8 NC LAN Vdc PoE shield The IP address SubNet Mask and Gateway of display have been programed at factory These values are printed on a label located on the...

Page 7: ...er This feature allows remote connection with display using a standard PC based Internet web browser Internet Explorer Mozilla Firefox etc Simply enter the numeric IP address of display into browser s...

Page 8: ...one by entering the Password in top right field of the browser window Default password is admin The password can be changed later in the administrator menu Press Login button or Enter to access the we...

Page 9: ...User Manual NDA 100 3 TH S RG L30 230AC PoE LAN 9...

Page 10: ...EDs Display s LED color will change automatically in dependence on displayed temperature value Blinking display When the alarm s upper or lower limits are exceeded display will be blinking Thermostat...

Page 11: ...bus ID number Sensor No 2 settings Sensor No 2 connect RS485 Ethernet None Select what type of sensor should be paired with display RS485 external sensor is attached to display via cable Ethernet LAN...

Page 12: ...e is selected above this value sets fixed LED brightness level from 1 to 100 If Automatic mode is selected above this value sets the slope of brightness regulation curve Default factory value is 90 MA...

Page 13: ...ds The RESET button is located near the external sensor connector P1 on the back panel Change administrator password Enter new password if you want to change it Default password is admin Click on the...