EL750
61 |
P a g e
The Following results are shown on Terminal screen.
10.050 ARMX 11.250 ARMY 5.560 ARMZ 8.850 ARMU
Symbol
Meaning
A
Absolute readings
I
Incremental
R
Radial
D
Diametric
X/Y/Z/U
Axes
M
MM
N
Inch
The Terminal Settings should be as under
Setting options
Values
Baud rate /Bits Per
second
9600 / 19200 / 38400 / 57600 / 115200
Data Bits
7 / 8
Parity
None / Even / Odd
Stop bits
1 / 2
Transmission mode
OFF / Continuous / Key press
Transmission Interval
(sec)
0.1 / 0.2 / 0.5 / 1 / 2 / 3 / 4 / 5 / 6 / 8 / 10
Continuous mode: -
In continuous mode the current displayed counts are transmitted to
PC and can be viewed on Terminal Software. Transmission interval for continuous mode is
programmable and following options are available 0.1 / 0.2 / 0.5 / 1 / 2 / 3 / 4 / 5 / 6 / 8 / 10
seconds.
Request mode: -
In this mode DRO will transfer current count only on receiving request
from terminal. Request can be generated by pressing ‘X’,’ Y’, ‘Z’ and ‘U’ keys on PC
keyboard for viewing respective axis reading. Press A key on keyboard for all axis reading.