EL750
23 |
P a g e
Navigate to Calibration Menu in axis setting
Select Linear Error Compensation {
} menu.
1. Perform Machine reference in the axis settings. Refer to Section 5.5 and 6.7. After
performing machine reference do not set or reset the axis till the complete SLEC
calibration is complete.
2. Divide the travel into user defined segments.
3. Enter into standard measurement mode (DRO mode).
4. Note down all the standard values and the observed values for each segment.
5. Enter the setup mode and select {
} for the respective axis.
6. Start entering the Slip values and observed values one by one.
7. Press {
} to move to the next segment, Repeat the procedure for each
segment.
8. Save & exit the menu.
Now the Nonlinear error compensation is stored and applied.Following is sample screen
shown
Note
If DRO is in SLEC compensation mode, “M/C Ref” message will appear after Power ON.