EL750
16 |
P a g e
5.1 General Settings:
Sr.
no.
User Setup
Parameters
Description
1
Sleep Mode Time
(min)
Defines Sleep Time Interval in minutes (5 to 120).
2
Key Beep Enable
To enable or disable keyboard beep ON or OFF.
3
Zero App. Beep En
To enable or disable Zero Approach Beep ON or OFF.
4
Zero App. Tolerance
This sets a tolerance value for Zero Value in Zero approach
modes.
5
Diagnostics
This can be used checking the Keyboard, Encoder, Probe,
and Display as diagnostic tool.
6
Select Axis
This is used for setting axis specific parameters. (Axis
parameters are given below in 5.2 & 5.3)
7
Serial
communication
Enables the user to set the Serial communications
parameters.
8
Recall OEM setting
Recalling OEM settings will reset all the users settings
related to Axis and Auxiliary I/O to Standard OEM setting.
9
Auxiliary Setup
This options enables user to configure auxiliary Inputs &
Outputs
10
Machine Model
User can select Mill or Lathe machine functionality as per
application requirement.
11
Save & Exit
To save the changes and exit from setup.
12
Exit without saving
Exit from setup without saving changes.
5.2 Axis Specific Settings (Linear Type):
1. Scale Resolution:
This option is available for all axes if configured as linear type.
The options available are 0.1 µm, 0.2 µm, 0.5 µm, 1 µm, 2 µm, 5 µm, 10 µm, 20
µm, 50 µm and 100 µm. The default value is
5µm
.
2. Display Resolution:
Option available for all axis, resolution settings available
are 0.1 µm, 0.2 µm, 0.5 µm, 1 µm, 2 µm,
5µm
, 10 µm, 20 µm, 50 µm and 100 µm
if the axis is configured as linear type.
3. Axis Direction:
The counting direction can be set either Left or Right for each
individual axis. The default value is
left
direction.
4. Axis Mode:
The Axis mode can be set either Radius or Diametric for each
individual axis. This is valid only if the DRO is configured as Lathe model. In Mill
model, all axes are forced to RAD mode.
5. Machine Reference:
Keep the encoder position near to the desired reference on
the encoder.