Evacuation system if several ironers are connected to a common
evacuation duct (except for the gas heating machines)
If several dryer ironers are installed with a common evacuation duct, the cross-section of the
evacuation duct must increase as a function of the number of installed machines so that each of
them operates at the same value of air resistance.
Use elbows (and not Tees) to allow
the air to pass forwards.
The simpli
fi
ed
fi
gure below shows
the principle on which the evacuation duct
shape is designed.
Number of ironers
D1
D2
D3
D4
Outlet diameter of the exhaust pipe in (mm)
160
225
315
450
Ventilation aperture required section
2 dm² 4 dm² 8 dm² 16 dm²
The indicated evacuation diameter is the dryer outlet diameter.
Cross-sections of ducts between dryers and the outside of the building must be designed taking
account of the
fl
ow and the allowable pressure loss on each machine and the routing of ducts
(elbows and lengths).
Please call us if you are in any doubt about the layout of your exhaust device if you are
modifying an existing installation.
Summary of Contents for IC4 4819 FFS
Page 1: ...Service manual IC4 4819 4825 4832 FFS Feeder Ironer Folder Stacker 04102011 GB 43 2015 ...
Page 2: ...This page is left blank on purpose ...
Page 4: ...This page is left blank on purpose ...
Page 5: ...1 04102011 GB 06 2009 Service Manual Safety ...
Page 6: ...This page is left blank on purpose ...
Page 10: ...This page is left blank on purpose ...
Page 12: ...This page is left blank on purpose ...
Page 16: ...This page is left blank on purpose ...
Page 18: ...This page is left blank on purpose ...
Page 26: ...This page is left blank on purpose ...
Page 55: ...10 27 Service Manual Installation 04102011 GB 51 2010 This page is left blank on purpose ...
Page 56: ...This page is left blank on purpose ...
Page 58: ...This page is left blank on purpose ...
Page 66: ...This page is left blank on purpose ...
Page 68: ...This page is left blank on purpose ...
Page 71: ...20 3 Service Manual Operation 04102011 GB 06 2009 This page is left blank on purpose ...
Page 72: ...This page is left blank on purpose ...
Page 74: ...This page is left blank on purpose ...
Page 114: ...This page is left blank on purpose ...
Page 178: ...This page is left blank on purpose ...
Page 180: ...This page is left blank on purpose ...
Page 192: ...This page is left blank on purpose ...
Page 194: ...This page is left blank on purpose ...
Page 200: ...This page is left blank on purpose ...
Page 202: ...This page is left blank on purpose ...
Page 209: ...25 7 Service Manual Gas heating 04102011 GB 50 2011 This page is left blank on purpose ...
Page 222: ...This page is left blank on purpose ...
Page 224: ...This page is left blank on purpose ...
Page 227: ...26 3 Service Manual Steam heating 04102011 GB 06 2009 This page is left blank on purpose ...
Page 230: ...This page is left blank on purpose ...
Page 232: ...This page is left blank on purpose ...
Page 236: ...This page is left blank on purpose ...
Page 238: ...This page is left blank on purpose ...
Page 244: ...This page is left blank on purpose ...
Page 246: ...This page is left blank on purpose ...
Page 256: ...This page is left blank on purpose ...
Page 258: ...This page is left blank on purpose ...
Page 267: ...30 9 Service Manual Feeding Motion 04102011 GB 21 2012 This page is left blank on purpose ...
Page 268: ...This page is left blank on purpose ...
Page 270: ...This page is left blank on purpose ...
Page 278: ...This page is left blank on purpose ...
Page 280: ...This page is left blank on purpose ...
Page 296: ...This page is left blank on purpose ...
Page 298: ...This page is left blank on purpose ...
Page 303: ...33 5 Service Manual Cross folding 04102011 GB 06 2009 This page is left blank on purpose ...
Page 310: ...12 33 KM12 Service Manual Cross folding 04102011 GB 06 2009 FC510 switch left casing support ...
Page 312: ...This page is left blank on purpose ...
Page 314: ...This page is left blank on purpose ...
Page 322: ...This page is left blank on purpose ...
Page 324: ...This page is left blank on purpose ...
Page 330: ...This page is left blank on purpose ...
Page 332: ...This page is left blank on purpose ...
Page 335: ...36 3 Service Manual Electrostatic bar 04102011 GB 43 2015 This page is left blank on purpose ...
Page 338: ...This page is left blank on purpose ...
Page 340: ...This page is left blank on purpose ...
Page 348: ...This page is left blank on purpose ...
Page 350: ...This page is left blank on purpose ...
Page 365: ...51 15 Service Manual Troubleshooting 04102011 GB 06 2009 This page is left blank on purpose ...
Page 366: ...This page is left blank on purpose ...
Page 367: ...This page is left blank on purpose ...
Page 368: ...www electrolux com laundrysystems Share more of our thinking at www electrolux com ...