3
2
mm
3555
4185
4815
mm
2575
3205
3835
mm
2295
2925
3555
mm
479
479
479
mm
457
457
457
mm
1910
2540
3170
m/min
1.5-11
1.5-11
1.5-11
m²
2.20
2.90
3.60
m²
2.10
2.70
3.40
kg/h
35
46
59
kg/h
38
48
59
kg/h
57
75
93
kg
1300
1545
1715
kg
1405
1545
1715
kg
1500
1650
1830
kg
175
175
175
m²
3.03
3.78
4.52
m²
1.78
1.78
1.78
mm
20 (3/4")
20 (3/4")
30 (3/4")
kPa
1000
1000
1000
mm
10 (3/8")
10 (3/8")
10 (3/8")
mm
20 (3/4")
20 (3/4")
20 (3/4"
Ø mm
160
160
160
m³/h
800
950
1010
Pa
880
880
880
Pa
200
200
200
Ø mm
6/8
6/8
6/8
bar
5.5-7
5.5-7
5.5-7
l/h
280
280
280
kW
2.9
2.9
3.2
kW
39
52
65
kWh
2.7
2.7
3
kW
35.75
46.10
56.75
kW
32.85
43.20
53.55
kWh
34.30
44.25
54.48
kW
2.9
2.9
3.2
kWh
2.7
2.7
3
kg/h
83
110
141
dm³
300
398
497
Service
Manual
Technical characteristics
04102011/GB
06.2009
Characteristics
IC44819FFS
IC44825FFS
IC44832FFS
A
Overall width
B
Ironer width
C
Width between feet
Ø cylinder
Gas / Electric heating
Steam heating
Effective working width
Ironing speed, mini-maxi
Heating surface
Gas / Electric heating
Steam heating
Capacity max. water evaporation, with 50 % residual moisture and 100 % cylinder utilization
(according to ISO 9398-1)
Gas heating / Dubixium
Electric heating / Dubixium
Steam heating
Ironer net weight
Gas heating / Dubixium
Electric heating / Dubixium
Steam heating
Stacker net weight
Ironer
fl
oor area
Stacker
fl
oor area
Connections
F
Main switch to connect electric main cable
G
Inlet for electric main cable
H
Steam inlet
Maximum supply pressure
I
Condensate return
J
Gas inlet
K
Drain of vapour or burnt gas
Exhaust air max. with no pressure at 15 °C
Total pressure with no
fl
ow
Admissible head loss on evacuation
L
Air inlet
Air pressure, mini-maxi
Consumption
Consumptions
Gas heating / Dubixium
Installed electric power
Installed heating power
Maximum electrical consumption
Electric heating / Dubixium
Installed electric power
Installed heating power
Maximum electrical consumption
Steam heating
Installed electric power
Maximum electrical consumption
Max. steam consumption at 900 kPa
Inner volume steam cylinder
Heat loss : 3 % of installed heating power
Technical characteristics
Summary of Contents for IC4 4819 FFS
Page 1: ...Service manual IC4 4819 4825 4832 FFS Feeder Ironer Folder Stacker 04102011 GB 43 2015 ...
Page 2: ...This page is left blank on purpose ...
Page 4: ...This page is left blank on purpose ...
Page 5: ...1 04102011 GB 06 2009 Service Manual Safety ...
Page 6: ...This page is left blank on purpose ...
Page 10: ...This page is left blank on purpose ...
Page 12: ...This page is left blank on purpose ...
Page 16: ...This page is left blank on purpose ...
Page 18: ...This page is left blank on purpose ...
Page 26: ...This page is left blank on purpose ...
Page 55: ...10 27 Service Manual Installation 04102011 GB 51 2010 This page is left blank on purpose ...
Page 56: ...This page is left blank on purpose ...
Page 58: ...This page is left blank on purpose ...
Page 66: ...This page is left blank on purpose ...
Page 68: ...This page is left blank on purpose ...
Page 71: ...20 3 Service Manual Operation 04102011 GB 06 2009 This page is left blank on purpose ...
Page 72: ...This page is left blank on purpose ...
Page 74: ...This page is left blank on purpose ...
Page 114: ...This page is left blank on purpose ...
Page 178: ...This page is left blank on purpose ...
Page 180: ...This page is left blank on purpose ...
Page 192: ...This page is left blank on purpose ...
Page 194: ...This page is left blank on purpose ...
Page 200: ...This page is left blank on purpose ...
Page 202: ...This page is left blank on purpose ...
Page 209: ...25 7 Service Manual Gas heating 04102011 GB 50 2011 This page is left blank on purpose ...
Page 222: ...This page is left blank on purpose ...
Page 224: ...This page is left blank on purpose ...
Page 227: ...26 3 Service Manual Steam heating 04102011 GB 06 2009 This page is left blank on purpose ...
Page 230: ...This page is left blank on purpose ...
Page 232: ...This page is left blank on purpose ...
Page 236: ...This page is left blank on purpose ...
Page 238: ...This page is left blank on purpose ...
Page 244: ...This page is left blank on purpose ...
Page 246: ...This page is left blank on purpose ...
Page 256: ...This page is left blank on purpose ...
Page 258: ...This page is left blank on purpose ...
Page 267: ...30 9 Service Manual Feeding Motion 04102011 GB 21 2012 This page is left blank on purpose ...
Page 268: ...This page is left blank on purpose ...
Page 270: ...This page is left blank on purpose ...
Page 278: ...This page is left blank on purpose ...
Page 280: ...This page is left blank on purpose ...
Page 296: ...This page is left blank on purpose ...
Page 298: ...This page is left blank on purpose ...
Page 303: ...33 5 Service Manual Cross folding 04102011 GB 06 2009 This page is left blank on purpose ...
Page 310: ...12 33 KM12 Service Manual Cross folding 04102011 GB 06 2009 FC510 switch left casing support ...
Page 312: ...This page is left blank on purpose ...
Page 314: ...This page is left blank on purpose ...
Page 322: ...This page is left blank on purpose ...
Page 324: ...This page is left blank on purpose ...
Page 330: ...This page is left blank on purpose ...
Page 332: ...This page is left blank on purpose ...
Page 335: ...36 3 Service Manual Electrostatic bar 04102011 GB 43 2015 This page is left blank on purpose ...
Page 338: ...This page is left blank on purpose ...
Page 340: ...This page is left blank on purpose ...
Page 348: ...This page is left blank on purpose ...
Page 350: ...This page is left blank on purpose ...
Page 365: ...51 15 Service Manual Troubleshooting 04102011 GB 06 2009 This page is left blank on purpose ...
Page 366: ...This page is left blank on purpose ...
Page 367: ...This page is left blank on purpose ...
Page 368: ...www electrolux com laundrysystems Share more of our thinking at www electrolux com ...