![Electrolux EWM09312 Service Manual Download Page 7](http://html.mh-extra.com/html/electrolux/ewm09312/ewm09312_service-manual_96426007.webp)
Technical Support - A.D.L.
7/70
599 74 23-12 Rev.00
3 DIAGNOSTICS
SYSTEM
3.1 Accessing
diagnostics
Do not start the procedure with the combination buttons pressed
Series 6
Series 7
Turn the appliance on at the
ON/OFF switch.
In series 7, the first LED in the
right-hand row lights up.
Only in series 6, turn the selector to
the first position on the right.
Press the
START/PAUSE
button
and the nearest
option
button
simultaneously (as shown in the
figure).
Hold the buttons/sensors
down/pressed until the LEDs and
symbols begin to flash in sequence
(approximately 3 seconds).
In the first position, the operation of the buttons, of the related LEDs and of the groups of symbols shown on the
LCD screen is checked; turn the programme selector dial
clockwise
to run the diagnostic cycle for the
operation of the various components and to read any alarms (see diagnostic test).
During this phase, if any key combination is pressed (except for the one relating to diagnostics), all the
combinations of options stored are deleted (Extra rinse, No buzzer, etc.) whereas for SERIES 9, the memories
with the customised programmes are also deleted.
3.2 Quitting the diagnostics system
To exit the diagnostic cycle, switch the appliance off, then back on and then off again.