Technical Support - A.D.L.
38/70
599 74 23-12 Rev.00
Is the door closed
correctly?
E41
E41: Door open (device with 3 connections)
E41
Maximum time exceeded (PTC = 15 seconds)
Detach the connectors and
measure on the component
(Fig. 9):
- between connectors 3 and 4,
the circuit must not be open
(measure the resistance value
of the PTC).
- on the other hand, between
connectors 4 and 5, the circuit
must be open (the numbers
are printed on the
component).
Is the door interlock ok?
To check the wiring, with the door
open, measure on the following
wiring connectors:
- between wire J5-2 and J5-3, the
circuit must NOT be open
(measure the resistance value of
the PTC).
- between wire J5-1 and J5-2, the
circuit must be OPEN.
Replace the door
lock and repeat
the diagnostic
cycle to check for
any further
alarms.
Replace the door lock.
Is the appliance working
correctly?
Check the mechanical coupling
between the door lock and the door
latch. Is the system efficient?
Close the door correctly and
repeat the diagnostic cycle to
check for any further alarms.
Replace the door latch/the
door.
Replace the main circuit board
and repeat the diagnostic cycle
to check for any further
alarms.
Repeat the diagnostic cycle to
check for any further alarms.
Measure the continuity
between connector J5 (main
circuit board) and the door lock
connector.
Is the wiring ok?
Replace the
wiring and repeat
the diagnostic
cycle to check for
any further
alarms.
Replace the main circuit board and repeat the diagnostic
cycle to check for any further alarms.
NO
YES
NO
NO
Y
E
S
Fig. 9
NO
NO
NO
If there are burns on the circuit board,
see page 68
!
Y
E
S
YES
YES
YES