![Electrolux EWM09312 Service Manual Download Page 35](http://html.mh-extra.com/html/electrolux/ewm09312/ewm09312_service-manual_96426035.webp)
Technical Support - A.D.L.
35/70
599 74 23-12 Rev.00
Drain the water from the tub.
Are the pressure switch tube and
pressure chamber unobstructed?
(disconnect the tube and blow into it
to make sure the system is
unobstructed)
(Fig. 2 and 8)
E32
E32: The analogue pressure switch causes an error during calibration
(At the start of every cycle, the appliance drains to empty the tub and creates a level 0 to
check the calibration of the analogue pressure switch
E32
Clean/replace the tube and/or the
pressure chamber and repeat the
diagnostic cycle completely to check for
any further alarms.
Select a washing cycle. After a few minutes, has the appliance filled
with water and is the motor running?
Check the drain system
(filter, drain pump, drain tube).
Is the appliance draining
correctly?
Repair the
drain
circuit.
Appliance ok
Replace the
analogue
pressure switch
and repeat the
diagnostic cycle
to check for any
further alarms.
NO
YES
NO
YES
YES
NO
Y
E
S
Check that all the connectors are correctly inserted
!
If there are burns on the circuit board,
see page 68
!
Fig. 2
Fig. 8