![Electrolux EWM09312 Service Manual Download Page 53](http://html.mh-extra.com/html/electrolux/ewm09312/ewm09312_service-manual_96426053.webp)
Technical Support - A.D.L.
53/70
599 74 23-12 Rev.00
Run the diagnostic cycle
and fill with water up to the
door level to make sure the
heating element is
completely submerged.
Measure between the wiring
connector J6-1/J6-2 and the
appliance body.
-(see Fig. 6)-
Is the circuit open?
E68
E68: Washing heating element leakage
E68
Detach the connector
and measure between
the heating element
and the earth contact.
- (see Fig. 15)-
Is the circuit
open?
Run phase
8
of the
diagnostic cycle, drain water
from the tub. Replace the
heating element and repeat
the diagnostic cycle to
check for any further alarms.
Check/replace the wiring and repeat the diagnostic cycle to
check for any further alarms.
Replace the main circuit
board and repeat the
diagnostic cycle to check for
any further alarms.
YES
NO
MAIN CIRCUIT
BOARD
∞
Ω
∞
Ω
∞
Ω
General earthing
connection
Washing heating
element
NO
YES
Check that all the connectors are correctly inserted
!
If there are burns on the circuit board,
see page 68
!
Fig. 4
Fig. 6
Fig. 15