![Electrolux EWM09312 Service Manual Download Page 54](http://html.mh-extra.com/html/electrolux/ewm09312/ewm09312_service-manual_96426054.webp)
Technical Support - A.D.L.
54/70
599 74 23-12 Rev.00
E69
E69: Washing heating element damaged
E69
Measure the resistance
value of the heating
element (
Ω
) between
terminals J6-1 ÷ J6-2 of the
wiring connector
-(see Fig. 4)-
Is the value correct?
(28÷31
Ω
for 230V/1750W)
Replace the circuit board
and repeat the diagnostic
cycle to check for any
further alarms.
Measure the resistance
value directly on the
terminals of the heating
element
(detach the connectors)
-(See fig 13)-
Is the value correct?
(28÷31
Ω
for 230V/1750W)
Replace the heating
element and repeat the
diagnostic cycle to check
for any further alarms.
Check/replace the wiring and repeat the diagnostic cycle to check
for any further alarms.
Fig.13
NO
Y
E
S
NO
Y
E
S
MAIN CIRCUIT
BOARD
General earthing
connection
Washing heating
element
28÷31
Ω
230V 1750W
28÷31
Ω
230V 1750W
Check that all the connectors are correctly inserted
!
If there are burns on the circuit board,
see page 68
!
Fig. 4