![Electrolux EWM09312 Service Manual Download Page 59](http://html.mh-extra.com/html/electrolux/ewm09312/ewm09312_service-manual_96426059.webp)
Technical Support - A.D.L.
59/70
599 74 23-12 Rev.00
E91
E91: Communication error between the display board and the main
circuit board
E91
Inconsistency between configuration values on starting the appliance
Check the wiring between the main circuit
board and the display board:
►
Detach and reconnect the connectors
on both boards several times.
►
Measure the continuity between
connector J10 (main circuit board)
and J3
(display board).
Is the wiring ok?
Replace the main circuit board and repeat
the diagnostic cycle to check for any
further alarms.
Is the appliance still displaying E91?
Replace / repair the wiring and repeat the
diagnostic cycle to check for any further
alarms.
NO
Y
E
S
Appliance ok
NO
Replace the display board and repeat the
diagnostic cycle to check for any further
alarms.
Y
E
S
DISPLAY
CIRCUIT
BOARD
DISPLAY
CIRCUIT BOARD
0
Ω
If there are burns on the circuit board,
see page 68
!