EC1
EC1: Water fill solenoid valves blocked
EC1
The flowmeter has to fill water even with the solenoid valve not piloted
Open the drawer to
check which solenoid
valve is leaking and
replace it.
Repeat the
diagnostic cycle to
check for any further
alarms.
Does the solenoid
valve start filling with
water as soon as the
appliance is turned on?
Open the drawer to check which
solenoid valve is leaking and measure
between the wiring connector of the
respective solenoid valve and the
appliance body to see if there is any
dispersion
(Fig. 6 and table 1).
Is there any dispersion?
Replace the main circuit
board and repeat the
diagnostic cycle to check for
any further alarms.
Does the
appliance fill with
water even when it
is turned off?
Replace the main circuit board
and repeat the diagnostic cycle to
check for any further alarms.
Replace the wiring and repeat the diagnostic cycle to check for any further alarms.
Y
E
S
NO
NO
NO
Y
E
S
Check that all the connectors are correctly inserted
!
If there are burns on the circuit board,
see page 68
!
Y
E
S
Between J13-1 and J13-3 washing solenoid
valve
Between J13-4 and J13-6 pre-wash solenoid
valve
Tab. 1
MAIN CIRCUIT
BOARD
1) Solenoid valve
for Pre-wash
2) Solenoid valve
for Wash
1
2
∞
Ω
Fig. 6