![Electrolux EWM09312 Service Manual Download Page 16](http://html.mh-extra.com/html/electrolux/ewm09312/ewm09312_service-manual_96426016.webp)
Technical Support - A.D.L.
16/70
599 74 23-12 Rev.00
ALA
R
M
CO
DE
Description
Possible fault
Action
Machine status
Reset
E31
Malfunction in electronic pressure
switch circuit
•
Wiring; Electronic pressure switch.
•
Main electronic circuit board.
Cycle stops with door locked
RESET
E32
Calibration error of the electronic
pressure switch
•
Drain tube kinked/clogged/improperly positioned.
•
Solenoid valve faulty.
•
Drain filter clogged/dirty.
•
Drain pump faulty.
•
Leaks from pressure switch water circuit.
•
Pressure switch defective;
•
Wiring; main circuit board.
Cycle paused
START/RESET
E35
Overflow
•
Water fill solenoid valve faulty.
•
Leaks from pressure switch water circuit.
•
Faulty
wiring.
•
Pressure switch faulty.
•
Main circuit board faulty.
Cycle interrupted.
Safety drain cycle.
Drain pump continues to operate (5 min. on, then
5 min. off. etc.)
RESET
E38
Internal pressure chamber is
clogged (water level does not
change for at least 30 sec. of
drum rotation)
•
Motor belt broken.
•
Pressure switch hydraulic circuit clogged.
Heating phase is skipped
RESET