Installation Information
2-6
Clearance Requirements
Installation in a Recess or Closet
If washer and dryer are installed in the same
closet, door ventilation is required: A minimum of
120 square inches (774.2 cm²) of opening, equally
divided at the top and bottom of the door, is
required. Louvered openings should be located3
inches (7.6 cm) from bottom and top of door. Air
openings are required to be unobstructed when a
door is installed. A louvered door with equivalent air
openings for the full length of door is acceptable.
IMPORTANT
DO NOT INSTALL THE WASHER:
1. In an area exposed to dripping water or
outside weather conditions. The ambient
temperature should never be below 60° F
(15.6° C) to maximize detergent
effectiveness.
2. In an area (garage or garage-type build
ing) where gasoline or other flammables
(including automobiles) are kept or
stored.
3. Floor MUST be solid with a maximum slope
of 1 inch (2.54 cm). To minimize vibration
or movement, reinforcement of the floor
may be necessary.
Figure 2-4. Closet Installation
Figure 2-5. Clearances
Summary of Contents for EWFLW65H - 27'' Front-Load Washer
Page 2: ......
Page 16: ...B Ba as si ic c I In nf fo or rm ma at ti io on n 1 14 Notes ...
Page 17: ...Installation Information 2 1 Section 2 Installation Information ...
Page 23: ...Installation Information 2 7 Installed Washer Dimensions ...
Page 39: ...Electronic Control 3 1 Section 3 Electronic Control ...
Page 41: ...Electronic Control 3 3 Wave Touch Washer Cycle Chart ...
Page 43: ...Electronic Control 3 5 IQ Touch Washer Cycle Chart ...
Page 63: ...4 1 Component Teardown Section 4 Component Teardown ...
Page 85: ...Troubleshooting 5 1 Section 5 Troubleshooting ...
Page 91: ...6 1 Wiring Diagrams Section 6 Wiring Diagrams ...