36
Installation manual
Power wiring
Incoming power wiring from the Wiring Harness Plate Assembly connects to the Pump Interface Printed Circuit Board
power terminal block (Found on Item 1, Replacement Parts List).
• 115 V
The live wire goes to terminal 1. The neutral wire goes to terminal 4. Black jumper between terminal 1 and terminal
2. White jumper between terminal 3 and terminal 4.
• 208/230 V
White jumper from terminal 2 to terminal 3
Motor voltage rating of installed motors must match power wiring configuration.