31
Service Information
40
Model
CLR2160
Prepare Plumbing
CAUTION
Plumbing installation must observe all state and
local codes. All water and drain connections MUST
BE made by a licensed/qualified plumbing
contractor. Failure to follow recommendations and
instructions may result in damage and/or harm.
Drain Connection
IMPORTANT
IMPORTANT
Drain can NOT be located directly below unit. Unit
has a solid base that will not allow unit to drain
below itself.
The CLR2160 can be installed using a gravity drain, a
factory-installed drain pump (U-Line P60) or a locally
installed drain pump. Drain lines must have a 5/8" inside
diameter. The floor drain must be large enough to
accommodate drainage from all attached drains.
Follow these guidelines when installing drain lines to
prevent water from flowing back into the ice maker
storage bin and/or potentially flowing onto the floor,
causing water damage:
Gravity Drain
A Gravity Drain may be used if:
• Drain line has at least a 1" drop per 48" of run
(1/4" per foot).
• Drain line does not create traps or created traps are
vented
(Figure 2)
.
Figure 2
See
Figure 3
for a typical gravity drain installation.
Figure 3
If using a gravity drain:
1. Attach the 5/8" ID drain connection on the back of the
unit to a 5/8" OD rigid tube, using a worm clamp.
2. Attach the other end of the rigid tube to your 5/8" ID
drain line with a worm clamp.
3. Insulate the drain line, if necessary, to prevent
condensation.
Factory-Installed Drain Pump
If your drain line will run up to a stand pipe, disposal
assembly or spigot assembly or does not otherwise meet
the requirements for a gravity drain, you may have
ordered the CLR2160 with a U-Line P60 drain pump. See
Figure 4
,
Figure 5
and
Figure 6
for typical installations
requiring a drain pump. If you need to install a P60 drain
pump into your unit, see
Locally-Installed Drain Pump
on page 42.
Figure 4
Normal
Proper Drain
With Trap
Poor Drainage, Water Will Back Up
With Trap and Vent
Proper Drain
ULIN_0569_A
Waste
Waste
Cold
Water
Shut-Off
Valve
Hot
Water
Gravity Drain
ULIN_0570_A
Cold
Water
Hot
Water
Waste
Waste
Shut-Off
Valve
Stand Pipe
ULIN_0571_A
E151M
E151M
EIMP60
EIMP60
33.
Summary of Contents for E15IM60GPS
Page 47: ......