- 21 -
DGS-TDS-N 05.09 A. B. © Electrolux
599 521 367
EN
4 3 2 1
3 2 1
1
1a
Input module
contacts of conductor plate 10mA/5Vdc
contact name of connector
Anschluß Datenleitung
Conductor plate
make contact 1a
make contact 1
The appropriate cooking zone relay which is located on the HOC2000 power board is provided with
voltage via the main switch (make contact) 1/1a of the cooking zone switch (input module). The
make contact is already closed from the first switching step. This corresponds to a rotation of 30°
(see wiring diagram).
Any other switching step, approx. 18° results in a change of a resistance value which is transmitted
by the conductor plate via data link to the HOC2000 user interface. So the input module works like
a potentiometer.
Behind every rotation there is a specific resistance value, which on the other hand stands for a
certain cooking level.
Fig.: wiring diagram input module