33
5995432258
motor reed switch. Make sure the shield is in place before
replacing the cover.
The cube motor operates on 120 VAC and has a
resistance of approximately 2K W.
To check the supply voltage to the cube motor, select
CUBED
on the ice dispenser control panel, then press the
dispenser pad to close the switch. Check for 120 VAC at
CN07 on the terminal block between pin #6 and pin #7.
The cube reed switch is mounted to the cube motor
housing. A small magnet is attached to the motor lift cam.
The magnetic operation of the reed switch informs the
power control Board (PCB) of the position of the cube
motor lift cam.
To check the cube reed switch:
1. Select
CUBED
on the ice dispenser control panel, then
press the dispenser pad to close the switch.
2. Check for 5 VDC at CN06 on the terminal block
between pin #3 and pin #7.
3. Select
CRUSHED
on the ice dispenser control panel,
then check for 0 VDC at the same pin location with the
dispenser switch in the closed position.
Summary of Contents for Built-In Dishwasher
Page 1: ...1 5995432258 Built in Side by Side Refrigerator May 2005 ...
Page 6: ...6 5995432258 ...
Page 7: ...7 5995432258 DISCONNECT POWER CORD BEFORE SERVICING IMPORTANT RECONNECT ALL GROUNDING DEVICES ...
Page 12: ...12 5995432258 Component Locator Views Component Locator Views ...
Page 13: ...13 5995432258 Refrigeration System Refrigeration Components ...
Page 28: ...28 5995432258 Control Board Connector Locator ...
Page 30: ...30 5995432258 Connector Description ...
Page 57: ...57 5995432258 leshooting Notes Schematics Warranty Troubleshooting Notes ...
Page 58: ...58 5995432258 Schematics ...
Page 59: ...59 5995432258 ...
Page 61: ...61 5995432258 Refer to Test Function above ...
Page 62: ...62 5995432258 ...
Page 63: ...63 5995432258 ...
Page 64: ...64 5995432258 ...
Page 65: ...65 5995432258 ...