The Digital Ground connection from P113 should connect to a single point on the Digital
Ground system installed during the front panel strap wiring process. Ideally, a central
point of connection would be a good place to connect the wire. For example, perhaps on
the Digital Ground line connecting the pattern switches or pattern LEDs together.
Analogue Board J15
1 2
P215
Analog Ground
Common
Connection
Figure 6-20: P215 Connections
The Analog Ground of P215 (which is the only signal carried by P215) should connect to
a single point on the strap-wired analog ground system of the front panel. Again, a good
place would be centrally located – perhaps on the analogue ground of the programming
pots.
66