Calibration Set Up
•
Set the Clock Enable Switch to OFF (IE, don’t clock the Klee during the
calibration).
•
Set all programming pots to full anti-clockwise.
•
Set the Range Switch to position 1.
•
Clip the negative (ground) lead of the DVM to analog ground. A good place to
connect it would be somewhere on the analog ground system of the panel – say
the ground lug of one of the programming pots.
Adjust R42
Adjust for 0V at Pin1 of U8
Figure 10-1: Register A Offset Zero Calibration
Register A Voltage Offset Zero Trim
•
Touch the tip of the positive DVM lead to pin 1 of U8.
•
While observing the DVM, adjust R42 for 0V on the DVM. Get as close to
absolutely zero volts as possible.