ELECTRO FREEZE Soft Serve Models SLX400, SLX400E, SLX500
14
Trouble Shooting Tables
(continued)
PROBLEM
PROBABLE
CAUSE
REMEDY
Compressor
and beater
motor do not
operate when
dispensing.
1.
Plunger switch(es) defective or out of
adjustment.
1.
Contact your Electro Freeze Distributor
for service.
2.
Out on HPCO or LPCO.
2.
Contact your Electro Freeze Distributor
for service.
Freezer runs
continually and
product gets too
cold.
1.
Plunger switch rod engaged.
1.
Close plunger completely.
2.
Plunger switch (side or center) out of
adjustment or defective.
2.
Contact your Electro Freeze distributor for
service.
3.
Starter points stuck.
3.
Contact your Electro Freeze distributor for
service.
4.
Suction pressure too low.
4.
Contact your Electro Freeze distributor for
service.
1.
Trouble in compressor condensing circuit.
1. See Troubleshooting Chart-
Compressor/Condensing Circuit Section
16.1
2.
Faulty start capacitor, run capacitor or
relay. (Single phase only)
2. Contact your Electro Freeze Distributor
for service.
3.
Faulty contactor.
3. Contact your Electro Freeze Distributor
for service.
Compressor
does not
operate or
operates
improperly.
4.
Disconnected or broken wire in switch or
capacitor relay box.
4. Contact your Electro Freeze Distributor
for service.