![ELECTRO FREEZE SLX400 Operator'S Manual With Replacement Parts List Download Page 49](http://html.mh-extra.com/html/electro-freeze/slx400/slx400_operators-manual-with-replacement-parts-list_2379661049.webp)
41
184599
ELECTRO FREEZE Soft Serve Model SLX400, SLX400E, SLX500
14
Trouble Shooting Tables
(continued)
PROBLEM
PROBABLE
CAUSE
REMEDY
1. Product too cold.
1.
Check product temperature. Should be
17° to 19°F (-8 to -7°C). See
Troubleshooting Table - Dispensed
product too hard.
2. Dispensing speed adjustment bolt too far
down.
2.
Contact your Electro Freeze distributor
for service.
Product
dispenses
slowly out of
dispensing
head.
3. Wrong rotation on beater.
3.
Have an electrician correct rotation to
clockwise as viewed from the front of the
freezer.
Dispensed
product too
hard.
1.
Controls are set too cold.
1.
Contact your Electro Freeze distributor for
service.
2.
Plunger switch electrically or
mechanically stuck closed.
2.
Contact your Electro Freeze distributor for
service.
3.
Low suction pressure.
3.
Contact your Electro Freeze distributor for
service.
Dispensed
product too soft.
1.
Dirty or blocked condenser, restricted
air flow.
1.
Unblock condenser or have cleaned by
your Electro Freeze distributor.
2. Component
failure.
2. Contact
your
local
service
company.
3.
Leak in refrigeration system resulting in
little or no refrigeration.
3.
Contact your local service company.