10.2.1
Standard Priming Instructions
10.2
Priming
Figure 10-3 Mix Feed Tube Assembly
Priming the freezer removes all excess
sanitizer from the freezing cylinder, and sets
the proper overrun for the first cylinder of
product.
1.
Make sure that your hands, fore-
arms, and all freezer assemblies are
sanitized.
2.
See figure 10-3. Insert the regulator
into the mix feed tube assembly. Place mix
feed tube on sanitized surface. Set to
desired port size number. Larger holes are
for thicker products. Insert the mix feed tube
assembly into the hopper drain outlet.
3. Proceed to instructions in section
10.2.1 or 10.2.2 depending on freezer setup.
REGULATOR
O RING
MIX FEED
TUBE
MIX INLET PORT
1.
Place a bucket under the dispense
head.
2.
While filling the mix hopper with
one gallon of mix open the plunger by
pulling the dispense handle down and allow
mix to push out remaining sanitizer. When
pure mix is flowing from the dispense head
close the dispense handle (figure 10-4).
Important:
Failure to completely remove sanitizer or
water from the freezing cylinder before
placing in
freeze will damage the
freezer.
Figure 10-4 Pure mix
3.
Allow mix to continue flowing into
the cylinder until the mix in the hopper stops
bubbling. Insert mix feed tube assembly.
4.
Press the
freeze button to start
the freezer.
5.
Repeat Steps 1 - 4 for the other side
of the freezer.
6. Sanitize and install nozzles.